Eureka on the web
When you want the answer in the next five minutes.
The agent works the prompt against patents and technical literature, citing every source.
Run your analysis now →Filing growth compares 2021 (22 records) with 2024 (14) — a three-year span. 2024 is the most recent year we treat as complete: publication lags filing by roughly 18 months, so 2025 onwards are still filling in and any growth rate that ends there would understate the field. Top-5 share is the combined record count of the five largest assignees divided by all 383 records in scope (CR5), not by the ranked leaders only.
This landscape covers 383 published records filed between 2015 and mid-2026 that describe bioabsorbable or resorbable fixation implants — including magnesium and polymer implant claims tied to degradation rate, hydrogen evolution, mechanical retention, osteolysis, radiolucency or sterilization effect. The search combines implant-material terms with the specific physiological and manufacturing effects that define this niche, rather than pulling in every general orthopedic implant filing.
Filing activity rose sharply after 2017, peaked in 2018, and has since cooled through the last fully-observable year of data. Ownership is concentrated among a handful of assignees but far from consolidated, and the technology mix splits between sterilization/degradation-control claims and structural implant claims that are frequently filed together.
Pick a task. Every answer cites the patents behind it.
The 383 records in scope span 2015 to mid-2026, with filing activity concentrated in the years following 2017 and a technology mix split between degradation-control and structural implant claims.
Filings rose from 7 in 2017 to a peak of 35 in 2018. The 2021-to-2024 span shows a -36% change (22 down to 14), but 2025 and 2026 figures are still filling in under the usual 18-month publication lag, so treat the most recent two years as incomplete rather than as evidence of a continued decline.
A61L (sterilising and disinfecting) appears on 53.0% of the 383 records and A61F (implants and prostheses) on 45.2%, together forming the field's core. Material-specific classes — alloys (C22C, 6.5%), polymer compositions (C08L, 6.3%) and electroplating (C25D, 5.7%) — are each present but far thinner, since a single record can carry several IPC classes these shares do not sum to 100%.
Shares are the percentage of the 383 records in scope. A patent can carry several IPC classes, so the shares add up to more than 100%.
This page is one run against one query. Ask Eureka your own question about bioabsorbable fixation implants and every answer comes back with the patent numbers behind it.
Try EurekaA bioabsorbable implant or its part consists of a structure having a varying characteristic in at least one direction, defining a gradient. The structure comprises a bioabsorbable polymer and another substance within or next to it, constituted of a wound or folded blank with a direction of variation in concentration, substance type, polymer type, or porosity, with a winding axis or fold lines set substantially perpendicular to that direction.Filed by Bioretec Oy, published 2006-12-20 — illustrates the folded/wound-blank construction method used to create graded implant properties.


| # | Publication no. | Patent title | Citations |
|---|---|---|---|
| 1 | US6306424B1 | Foam composite for the repair or regeneration of tissue | 1,863 |
| 2 | US20100191292A1 | Oriented polymer implantable device and process for making same | 1,244 |
| 3 | EP1234587A1 | Biocompatible foam composite | 953 |
| 4 | US20040013703A1 | Bioabsorbable plugs containing drugs | 182 |
| 5 | US20060199876A1 | Bioceramic composite coatings and process for making same | 176 |
| 6 | US5856367A | Biocompatible porous matrix of bioabsorbable material | 166 |
| 7 | US20110238075A1 | Drug delivery devices and methods | 149 |
| 8 | US20030077311A1 | Foam composite for the repair or regeneration of tissue | 142 |
| 9 | US6013104A | Implant with reinforced resorbable stem | 133 |
| 10 | US8529492B2 | Drug delivery devices and methods | 115 |
Citation counts are drawn from within this searched corpus and favour older filings; treat them as a signal of accumulated influence rather than current filing activity.
Each row carries its publication number; clicking a row searches Eureka by that number.
When you want the answer in the next five minutes.
The agent works the prompt against patents and technical literature, citing every source.
Run your analysis now →When it has to run inside your own pipeline.
Patent search, landscape analysis and assignee resolution as MCP tools. Drop them into any agent framework, or call REST directly.
Browse MCP servers →Beyond the raw counts, a few patterns in this dataset matter for anyone deciding where to file or where to challenge existing claims.
The top 5 assignees hold 112 of the 383 records in scope, and the top 10 hold 176 (46.0%). That leaves more than half the field spread across a long tail of smaller filers, so the space is contested rather than owned outright by any single company.
US6306424B1 carries 1,863 citations and US20100191292A1 carries 1,244 — both far ahead of the rest of the corpus. High citation counts in an older filing reflect accumulated influence over time, not that the underlying approach is still the most active one being filed today.
A61L sterilising and disinfecting claims appear on 53.0% of the 383 records, while magnesium and other alloy claims under C22C sit at just 6.5%. That gap indicates most patent activity treats degradation and sterilization behaviour as the primary inventive angle rather than the base material itself.
Filings dropped from 22 in 2021 to 14 in 2024. Given the roughly 18-month lag between filing and publication, 2025 and 2026 figures are still incomplete, so this measured decline should not be extrapolated further without newer data.
Eureka can read the same corpus for gaps instead of for coverage: under-claimed branches adjacent to bioabsorbable fixation implants, with the prior art for and against each one.
The ranked assignee list covers 100 companies by record count. Filing is concentrated at the top but the field is far from closed, and recent-year momentum data suggests even the leading filers have slowed in the most recent, still-incomplete years.
The top-ranked assignee holds 32 of the 383 records in scope, with the fifth-place filer at 15 and tenth place at 10 — a steep but not runaway drop-off that leaves meaningful room for new entrants to build a comparable position.
The top 5 assignees combined account for 112 records, or 29.2% of the total in scope. That is meaningful concentration without being dominant, meaning freedom-to-operate analysis still needs to account for a broad set of smaller holders.
Only 8 co-assignee pairs appear across the dataset, with the strongest pairing recorded at 11 shared records between two assignees. Most filers in this space patent independently rather than through joint ventures or shared assignments.
Recent-year momentum data shows the top assignees, including the field leader, at zero filings in the latest year, with one recording a -100% year-on-year change. Given the 18-month publication lag, this is more likely incomplete data than an actual stop in filing.
| Assignee | Recent year | YoY |
|---|---|---|
| Spirox Inc | 0 | — |
| Tryton Medical Inc | 0 | — |
| Abbott Cardiovascular Systems Inc | 0 | — |
| Stryker Corp | 0 | — |
| Vanderbilt University | 0 | — |
| Poly-Med Inc | 0 | -100% |
| KAMPNER STANLEY L | 0 | — |
| Zorion Medical Inc | 0 | — |
The trends here point to specific follow-up work depending on whether you are filing, defending, or scouting for acquisition targets.
With 29.2% of filings held by the top 5 assignees and a dense overlap between sterilization and implant-geometry claims, a targeted claim chart against the most-cited records is the fastest way to see what is actually blocked.
Run a claim comparison in EurekaAlloy and polymer-composition classes sit well below the dominant sterilization claims, suggesting room for narrowly-drafted filings that pair a specific material formulation with a measured degradation or retention outcome.
Explore white space in EurekaRecent-year filing counts are incomplete for 2025 and 2026; revisiting the trend data in six to twelve months will show whether the 2021-2024 decline continued or reversed.
Set a monitoring alert in EurekaThe dominant classes in this dataset are A61L (sterilising and disinfecting), present on 53.0% of the 383 records in scope, and A61F (implants and prostheses), present on 45.2%. Smaller but distinct bands cover diagnosis and surgery methods (A61B, 22.7%), medicinal preparations (A61K, 10.7%), alloys (C22C, 6.5%), and polymer compositions (C08L, 6.3%). Because a single filing can carry several IPC codes, these percentages overlap rather than sum to 100%, and they reflect where claim activity actually clusters rather than a clean technology taxonomy.
The ranked leaders in this dataset span 100 companies counted by record, with the top filer holding 32 records and the fifth-ranked holding 15. The top 5 filers combined account for 112 of the 383 records in scope, or 29.2%, and the top 10 account for 176, or 46.0% — meaning close to half the field's activity sits with a small group, while the remainder is spread across a long tail of single- or few-filing entrants. This is a concentration pattern worth checking before assuming the field is wide open.
Filings peaked at 35 in 2018 after starting at 7 in 2017, and the measurable recent trend shows a -36% change from 22 filings in 2021 to 14 in 2024. Because publication typically lags actual filing by roughly 18 months, the 2025 and 2026 figures in any dataset are still incomplete and should not be read as a continuing decline — they simply have not caught up yet. The safest reading is that the field has cooled from its 2018 peak but has not been characterized by data recent enough to call it dormant.
EP1733746A2, assigned to Bioretec Oy and filed in 2006, claims a bioabsorbable implant built from a folded or wound blank whose properties — polymer type, additive concentration, or porosity — vary along a defined direction to create a gradient structure. This claim language is specific to that folding/winding construction method, so implants that achieve a similar graded effect through a different manufacturing approach, such as layered extrusion, are less likely to fall inside its literal scope. Anyone designing a gradient-property implant should still run a jurisdiction-specific freedom-to-operate check given the age of the filing.
The thinnest documented bands relative to the 383-record base are polymer-composition claims under C08L (6.3%) and body-fluid device claims under A61M (7.8%), both well below the dominant A61L and A61F classes. These lighter bands suggest less-claimed intersections, particularly combining a specific polymer blend with a measured degradation profile rather than repeating implant-geometry claims that are already dense under A61F. Receiving-office data also shows lighter filing volumes in Canada and Australia (20 and 18 respectively) compared with 139 in the United States, which is worth factoring into a filing strategy.
Go past this page: query the whole bioabsorbable fixation implants corpus yourself, in your own scope.
Every answer comes back with patent numbers you can open.
Disclaimer. This page is generated from Patsnap Eureka data drawn from a limited snapshot of global patent and scientific-literature records, and is provided for general information and reference only.
Patent data carries inherent limitations: recent filings (typically the most recent 18–24 months) are under-counted due to standard publication lag; counts may be reported at either a patent-family or a patent-record basis and are not always directly comparable; classification, applicant-name, and citation data may contain errors, duplicates, or omissions; and the underlying search query defines and constrains the scope shown. As a result, the analysis may be incomplete or inaccurate and may not reflect the full technology landscape.
Nothing on this page constitutes an exhaustive prior-art, novelty, freedom-to-operate, or validity search, nor does it constitute legal, financial, investment, or professional advice, and it should not be relied upon as such. Any patent, commercial, or strategic decision should be verified independently and reviewed with qualified patent, legal, and domain professionals. Patsnap makes no warranties, express or implied, as to the accuracy, completeness, or fitness for any particular purpose of the information presented.
Machine translation. Assignee and organisation names originally recorded in Chinese, Japanese or Korean have been rendered into English by an AI translation step so that the tables stay readable. These renderings are best-effort and may not match a company's registered English name; the original name is what the underlying patent record carries, and it is what any Eureka query launched from this page uses.
Help us improve
Something wrong, out of date, or missing on this page? Tell us and it goes straight to the team that maintains it.
This page