Eureka on the web
When you want the answer in the next five minutes.
The agent works the prompt against patents and technical literature, citing every source.
Run your analysis now →A data-led view of centrifugal pump mechanical seal leakage monitoring patents: filing trends 2015-2026, IPC composition, leading assignees and the claims that anchor the field.
Filing growth = 2021 (58 records) → 2024 (37); 2024 is the last year we treat as complete. Top-5 share = the 5 largest assignees ÷ all 2,155 records in scope (CR5), not the ranked leaders only.
Centrifugal pump mechanical seal leakage monitoring sits at the intersection of pump design, seal engineering and condition-monitoring instrumentation. Across the 2,155 records in scope from 2015 through the 2026 data cut-off, filing activity concentrates heavily in pump-housing classifications rather than in seal components treated as standalone parts. No single company controls the space — the leading assignees hold small, roughly comparable shares, and the most-cited underlying claims date back to the 1990s, meaning newer filings largely build sensing and diagnostic layers on top of long-established mechanical leak-detection structures.
Filing rose steadily through the late 2010s, peaked in 2019, and has cooled through the most recent complete year of data. That trajectory, combined with a classification map dominated by pump-system claims over dedicated seal-gasket claims, points to a field where the mechanical leak-detection path is well-trodden and the sensing/diagnostic layer is where remaining differentiation sits.
Pick a task. Every answer cites the patents behind it.
The 2,155 records in scope span 2015 through the 2026 cut-off, with filing activity concentrated in pump-housing and seal-gasket classifications rather than spread evenly across adjacent mechanical branches.
Filings rose from 26 in 2017 to a peak of 81 in 2019, then declined through the complete-year data: 58 in 2021 down to 37 in 2024, a 36% drop over that span. 2025 and 2026 figures are still incomplete because publication typically lags filing by around 18 months.
Publication lags filing by roughly 18 months, so 2025 onwards are still filling in. Growth rates on this page therefore end at 2024; running them to the last bar would understate the field.
Non-positive-displacement pumps (F04D) carry 46.8% of the 2,155 records, more than four times the share of the second-largest class, seals and gaskets (F16J) at 16.3%. Rotary pumps, positive-displacement pumps, drilling, turbines, motors and bearing/coupling classes each hold single-digit shares, marking them as secondary rather than primary filing targets.
Shares are the percentage of the 2,155 records in scope. A patent can carry several IPC classes, so the shares add up to more than 100%.
This page is one run against one query. Ask Eureka your own question about centrifugal pump mechanical seal leakage monitoring patent landscape and every answer comes back with the patent numbers behind it.
Try EurekaThe seal assembly comprises a housing, a shaft, seals, and a reservoir. The housing has a hollow section bounded by a cylindrical surface and a first curved protrusion, with a first channel and a second channel extending from the hollow section. The shaft extends through the hollow section, and seals form a chamber around it. The curved protrusion and sleeve cooperatively form a hydraulic pump that conveys lubricating fluid from the chamber to the reservoir via the first channel, with fluid circulated back via the second channel. The assembly includes a fluid level gauge to signal leakage.Filed by Sundyne Corporation, 1996-10-08 — a structural leak-detection design that predates the field's busiest filing years and still anchors claim scope for reservoir-and-channel leak paths.


| # | Publication no. | Patent title | Citations |
|---|---|---|---|
| 1 | US6330525B1 | Method and apparatus for diagnosing a pump system | 506 |
| 2 | US6260004B1 | Method and apparatus for diagnosing a pump system | 500 |
| 3 | US20030201098A1 | In situ recovery from a hydrocarbon containing formation using one or more simulations | 310 |
| 4 | US20040020642A1 | In situ recovery from a hydrocarbon containing formation using conductor-in-conduit heat sources with an elec… | 306 |
| 5 | US20030196789A1 | In situ thermal processing of a hydrocarbon containing formation and upgrading of produced fluids prior to fu… | 297 |
| 6 | US20030079877A1 | In situ thermal processing of a relatively impermeable formation in a reducing environment | 297 |
| 7 | US20030146002A1 | Removable heat sources for in situ thermal processing of an oil shale formation | 278 |
| 8 | US20040040715A1 | In situ production of a blending agent from a hydrocarbon containing formation | 238 |
| 9 | US5770149A | Extracorporeal blood oxygenation system having integrated blood pump, heat exchanger and membrane oxygenator | 236 |
| 10 | US20030080604A1 | In situ thermal processing and inhibiting migration of fluids into or out of an in situ oil shale formation | 227 |
Ranked by citation count within the searched corpus; older records accumulate citations simply by having existed longer, so treat this as a signal of influence rather than of current commercial relevance.
Each row carries its publication number; clicking a row searches Eureka by that number.
When you want the answer in the next five minutes.
The agent works the prompt against patents and technical literature, citing every source.
Run your analysis now →When it has to run inside your own pipeline.
Patent search, landscape analysis and assignee resolution as MCP tools. Drop them into any agent framework, or call REST directly.
Browse MCP servers →Four figures from this dataset matter more than the rest for anyone deciding where to file, watch, or design around existing claims.
The five leading assignees combined hold only 6.4% of the 2,155 records in scope, and the top 10 add up to just 10.3%. That is a long tail of single- and few-filing entrants rather than a handful of gatekeepers controlling the space.
Activity rose to a peak of 81 filings in 2019, then declined through the last complete comparison year: 58 filings in 2021 down to 37 in 2024. Later years look thinner still, but that reflects publication lag, not confirmed decline.
Non-positive-displacement pump claims (F04D) cover nearly half of all 2,155 records, dwarfing dedicated seal-and-gasket claims (F16J) at 16.3%. Most active claim-writing treats leak monitoring as a pump-system feature, not a standalone seal component.
China's receiving office recorded 540 filings, ahead of the United States (433) and United Kingdom (329). The EPO, Australia and WIPO PCT route show more moderate but still meaningful volumes, reflecting a genuinely multi-jurisdiction field.
Eureka can read the same corpus for gaps instead of for coverage: under-claimed branches adjacent to centrifugal pump mechanical seal leakage monitoring patent landscape, with the prior art for and against each one.
This overview surfaces the shape of the field. Deeper questions — freedom-to-operate on specific claim structures, or which adjacent branches are worth a first filing — need claim-level analysis.
The most-cited records in this field date back decades and still anchor claim scope on leak-detection structure. Before filing a new mechanical design, chart it against these older claims directly.
Run a claim chart in Eureka →Bearing, coupling and motor-adjacent classifications carry meaningful record counts but thin dedicated claim density. That gap is worth testing against a specific product design.
Explore white space in Eureka →With no single leader controlling the field, watching which assignees are compounding filings year over year matters more than a static snapshot.
Set up assignee tracking in Eureka →The assignee ranking covers 100 companies drawn from the 2,155 records in scope, and the field is not dominated by a single player: the top 5 combined hold only 6.4% of all records and the top 10 combined hold 10.3%. That leaves a long tail of single- or few-filing entrants rather than a small set of gatekeepers. Practically, this means freedom-to-operate work should focus on specific claim clusters and older foundational patents rather than trying to clear one company's whole portfolio.
Filing activity peaked in 2019 at 81 records and has declined since, with the last fully-countable comparison showing a drop from 58 filings in 2021 to 37 in 2024 — a 36% decrease over that three-year span. Figures for 2025 and 2026 look lower still, but that reflects the roughly 18-month lag between filing and publication rather than a real collapse in activity. Treat any apparent recent-year dip with that lag in mind before concluding the field has gone quiet.
Non-positive-displacement pumps, IPC subclass F04D, covers 46.8% of the 2,155 records in scope, making it by far the largest single classification. Seals, gaskets and pistons (F16J) is a distant second at 16.3%. Because a single record can carry multiple IPC classes, these percentages add up to more than 100%, and they should be read as a density measure of where claim language sits, not as a partition of the whole field.
US5562406A, assigned to Sundyne Corporation and filed in 1996, claims a seal assembly where a housing-and-shaft chamber is fed by a hydraulic pump structure (a curved protrusion and sleeve) that circulates lubricating fluid between the chamber and an external reservoir through two channels, monitored via a fluid level gauge. Any new design that reproduces that specific two-channel circulation-and-gauge structure for leak detection sits inside its claim scope. Designs that detect leakage through other means — acoustic, vibration, or electrical signature sensing integrated into the pump housing, for instance — generally fall outside it.
Among the receiving offices in this dataset, China leads with 540 filings, ahead of the United States at 433 and the United Kingdom at 329. The European Patent Office, Australia and the WIPO PCT route each show more moderate volumes. This spread suggests filers are pursuing protection across multiple major markets rather than concentrating in a single jurisdiction, which is typical for pump and seal technology sold into global industrial and oil-and-gas markets.
Go past this page: query the whole centrifugal pump mechanical seal leakage monitoring patent landscape corpus yourself, in your own scope.
Every answer comes back with patent numbers you can open.
Disclaimer. This page is generated from Patsnap Eureka data drawn from a limited snapshot of global patent and scientific-literature records, and is provided for general information and reference only.
Patent data carries inherent limitations: recent filings (typically the most recent 18–24 months) are under-counted due to standard publication lag; counts may be reported at either a patent-family or a patent-record basis and are not always directly comparable; classification, applicant-name, and citation data may contain errors, duplicates, or omissions; and the underlying search query defines and constrains the scope shown. As a result, the analysis may be incomplete or inaccurate and may not reflect the full technology landscape.
Nothing on this page constitutes an exhaustive prior-art, novelty, freedom-to-operate, or validity search, nor does it constitute legal, financial, investment, or professional advice, and it should not be relied upon as such. Any patent, commercial, or strategic decision should be verified independently and reviewed with qualified patent, legal, and domain professionals. Patsnap makes no warranties, express or implied, as to the accuracy, completeness, or fitness for any particular purpose of the information presented.
Machine translation. Assignee and organisation names originally recorded in Chinese, Japanese or Korean have been rendered into English by an AI translation step so that the tables stay readable. These renderings are best-effort and may not match a company's registered English name; the original name is what the underlying patent record carries, and it is what any Eureka query launched from this page uses.
Help us improve
Something wrong, out of date, or missing on this page? Tell us and it goes straight to the team that maintains it.
This page