Run your analysis now →A patent landscape review of district heating pipeline leak monitoring: filing trends since 2017, the IPC composition across F17D and F24D, the concentration of filings among ranked assignees, and where claim space remai
Filing growth = 2021 (27 records) → 2024 (28); 2024 is the last year we treat as complete. Top-5 share = the 5 largest assignees ÷ all 367 records in scope (CR5), not the ranked leaders only.
District heating pipeline leak monitoring sits at the intersection of two IPC subclasses that rarely overlap this cleanly elsewhere: F17D, pipeline transport, and F24D, domestic heating systems. The 367 records in scope were pulled from filings that combine district heating network or heat distribution pipe language with leak detection, leakage monitoring, pipe fault detection or pressure monitoring claims. That combination narrows the field to systems built specifically for buried or insulated heat-distribution infrastructure, rather than generic pipeline sensing that happens to mention heat.
Coverage runs from 2015 through the 2026-08-31 data cut-off, though publication lags filing by roughly 18 months, so the most recent one to two years understate actual filing activity. The receiving-office split and the technology composition below reflect where the operational pressure to instrument ageing district heating networks is concentrated, and where claim space is still comparatively open.
Three views of the same 367-record dataset: how filing has moved year over year, which IPC subclasses carry the claims, and which patent offices are receiving them.
Filings peaked at 31 in 2017 and have since settled into a narrower band; the complete-year comparison from 2021 (27) to 2024 (28) shows a modest 4% increase rather than a clear upward or downward trend. 2025 and 2026 figures are still filling in as later-filed applications publish.
Publication lags filing by roughly 18 months, so 2025 onwards are still filling in. Growth rates on this page therefore end at 2024; running them to the last bar would understate the field.
F17D (pipeline transport) and F24D (domestic heating systems) each appear in roughly half of all 367 records — 51.0% and 50.4% respectively — confirming that most filings treat leak monitoring as inseparable from the heating-distribution hardware itself. Supporting classes like F16L (pipes and fittings, 10.6%), G01M (testing and structure balance, 10.4%) and G01N (material analysis, 3.0%) appear far less often, marking them as secondary claim territory rather than the primary battleground.
Shares are the percentage of the 367 records in scope. A patent can carry several IPC classes, so the shares add up to more than 100%.
This page is one run against one query. Ask Eureka your own question about district heating pipeline leak monitoring patent landscape and every answer comes back with the patent numbers behind it.
Try EurekaA pipeline fault detection system, method and sensor head suitable for use in the system are disclosed. The system comprises a vibro-acoustic sensor connectable to a fluid path of a pipeline and a remote monitoring system, the sensor being operable to measure one or more predetermined vibro-acoustic properties of the fluid and/or fluid path and communicate data on said measurements to the remote monitoring system, the remote monitoring system being arranged to monitor said data over time and being further arranged to screen the monitored data for characteristics representing a fault type to identify occurrence of a fault type in the pipeline.Filed by Syrinix Limited, published 2018-10-09. Chosen here as representative of the vibro-acoustic sensing approach to pipeline fault detection.


| # | Publication no. | Patent title | Citations |
|---|---|---|---|
| 1 | US6176046B1 | Portable, pre-manufactured, modular natural gas delivery stations | 67 |
| 2 | US3890787A | Method and means for heating buildings in a district heating system with waste heat from a thermal power plant | 35 |
| 3 | US20190293302A1 | Subatmospheric heating and cooling system | 33 |
| 4 | US20140034743A1 | Vapor vacuum heating systems and integration with condensing vacuum boilers | 32 |
| 5 | US20180216784A1 | Circulating inert-gas seal system based on gas-supply servo device and QHSE based storage and transportation … | 31 |
| 6 | WO2017089846A1 | Process for feeding an inhibitor into a gas pipeline for preventing gas hydrate formation | 26 |
| 7 | US6220520B1 | Manifolds for use in water heat distribution systems | 26 |
| 8 | WO2018015508A1 | Reduction of the return temperature in district heating and increasing of the return temperature in district … | 23 |
| 9 | WO1999054665A1 | Heat transferring device | 23 |
| 10 | CN206258226U | 一种基于热水介质的热力管线泄漏监测系统 | 19 |
Citation counts favour older filings within any searched corpus and should be read as a signal of influence on the field, not as a measure of current commercial importance.
Patent titles are shown in the language they were filed in, not translated, so that each record stays verifiable against the original filing — a translated title will not match in Eureka or in any national register. Each row carries its publication number; clicking a row searches Eureka by that number.
When you want the answer in the next five minutes.
The agent works the prompt against patents and technical literature, citing every source.
Run your analysis now →When it has to run inside your own pipeline.
Patent search, landscape analysis and assignee resolution as MCP tools. Drop them into any agent framework, or call REST directly.
Browse MCP servers →Four patterns worth acting on before drafting or licensing decisions.
The top-ranked assignee holds 13 records, with fifth place at 6 and tenth place at 4. Combined, the top 5 account for 11.7% of all 367 records and the top 10 for 17.2% — meaningful clustering, but nowhere close to a single dominant filer controlling the space.
China received 248 of the tracked filings, dwarfing the United States (26), United Kingdom (20), EPO (18), Canada (13) and WIPO/PCT (8) combined. That skew reflects the scale of district heating infrastructure under active retrofit and instrumentation in China relative to other tracked jurisdictions.
F17D and F24D each cover roughly half the corpus, meaning most inventors frame leak monitoring as a property of the heating system rather than a bolt-on pipeline sensor. Secondary classes like F16L, G01M and G01N sit well below 11% each, suggesting the sensing and materials-testing layers are comparatively under-claimed relative to the core system claims.
The 2017 peak of 31 filings has not been repeated, but the complete-year comparison from 2021 to 2024 shows a 4% increase rather than decline. Because publication lags filing by about 18 months, the lower counts visible in 2025 and 2026 reflect reporting lag, not an actual drop in filing activity.
Eureka can read the same corpus for gaps instead of for coverage: under-claimed branches adjacent to district heating pipeline leak monitoring patent landscape, with the prior art for and against each one.
The landscape points to specific questions worth running deeper diligence on before committing R&D or freedom-to-operate budget.
US10094732B2 and similar filings use vibro-acoustic sensor heads rather than pressure-differential methods. Understanding how tightly this sub-approach is claimed, versus the broader pressure-monitoring claims, changes where a new sensor design can safely sit.
Explore sensing approachesWith 17.2% of all 367 records held by just ten assignees, a targeted search against those specific portfolios is more efficient than a full-field clearance search.
Run a targeted FTO checkTesting, structure-balance and material-analysis claims sit at 10.4% and 3.0% of records respectively — far behind the core F17D/F24D claims. That gap is where a differentiated diagnostic method has room to file cleanly.
Investigate white spaceThe ranked assignee list covers 100 companies, with the leader holding 13 of the 367 records in scope and the fifth-ranked assignee holding 6. The top 5 assignees together account for 11.7% of all records and the top 10 for 17.2%, which means filing is clustered at the top but far from dominated by a single company. Most of the ranked list consists of assignees with only one or two filings, so the field has a long tail of operators, research institutes and individual inventors alongside the more active filers. This pattern suggests newer entrants can still stake out defensible claim territory rather than facing a single blocking incumbent.
The two dominant IPC subclasses are F17D (pipeline transport), covering 51.0% of the 367 records, and F24D (domestic heating systems), covering 50.4%. Because a single filing can carry multiple IPC codes, these two figures overlap heavily rather than summing cleanly. Supporting classes include F16L for pipes and fittings (10.6%), G01M for testing and structure-balance methods (10.4%), and smaller shares for F28D heat-exchange apparatus, G05D non-electric variable control, F24H fluid heaters and G01N material analysis, each in the 3% to 4% range. The concentration in F17D and F24D shows that most inventors treat leak monitoring as a core heating-system function rather than an add-on sensor category.
Filings peaked at 31 in 2017 and have not returned to that level since, but the most recent complete-year comparison — 27 filings in 2021 rising to 28 in 2024 — shows a modest 4% increase, not a decline. Any apparent drop-off in 2025 and 2026 reflects publication lag rather than an actual slowdown, since patent publication typically trails the original filing date by around 18 months. Treat 2024 as the last year with a reliable complete count. Overall the trend reads as a plateau following an early peak, rather than either sustained growth or retreat.
China is by far the largest receiving office in this dataset with 248 of the tracked filings, followed by the United States at 26, the United Kingdom at 20, the European Patent Office at 18, Canada at 13 and the WIPO/PCT route at 8. That imbalance likely reflects the scale of district heating infrastructure retrofit and instrumentation programmes underway in China relative to the other tracked jurisdictions. Companies evaluating freedom-to-operate risk should weight their search strategy toward Chinese filings accordingly, since the bulk of the recent activity sits there rather than in Europe or North America.
US10094732B2, assigned to Syrinix Limited and published in October 2018, claims a pipeline fault detection system built around a vibro-acoustic sensor head connected to a pipeline's fluid path and a remote monitoring system. The remote system screens sensor data over time for characteristics matching known fault signatures, rather than relying solely on instantaneous pressure thresholds. It appears in this landscape as a representative example of the vibro-acoustic sensing approach to leak and fault detection, one of several distinct technical routes documented in the corpus alongside pressure-differential and other monitoring methods. Reviewing its specific claim language is a reasonable first step before designing a new sensor-based monitoring system for district heating pipes.
Go past this page: query the whole district heating pipeline leak monitoring patent landscape corpus yourself, in your own scope.
Every answer comes back with patent numbers you can open.
Disclaimer. This page is generated from Patsnap Eureka data drawn from a limited snapshot of global patent and scientific-literature records, and is provided for general information and reference only.
Patent data carries inherent limitations: recent filings (typically the most recent 18–24 months) are under-counted due to standard publication lag; counts may be reported at either a patent-family or a patent-record basis and are not always directly comparable; classification, applicant-name, and citation data may contain errors, duplicates, or omissions; and the underlying search query defines and constrains the scope shown. As a result, the analysis may be incomplete or inaccurate and may not reflect the full technology landscape.
Nothing on this page constitutes an exhaustive prior-art, novelty, freedom-to-operate, or validity search, nor does it constitute legal, financial, investment, or professional advice, and it should not be relied upon as such. Any patent, commercial, or strategic decision should be verified independently and reviewed with qualified patent, legal, and domain professionals. Patsnap makes no warranties, express or implied, as to the accuracy, completeness, or fitness for any particular purpose of the information presented.
Machine translation. Assignee and organisation names originally recorded in Chinese, Japanese or Korean have been rendered into English by an AI translation step so that the tables stay readable. These renderings are best-effort and may not match a company's registered English name; the original name is what the underlying patent record carries, and it is what any Eureka query launched from this page uses.
Help us improve