Eureka on the web
When you want the answer in the next five minutes.
The agent works the prompt against patents and technical literature, citing every source.
Run your analysis now →A data-backed look at refrigerator food load and cooling recovery control patents: who leads filing, where activity concentrates by IPC class, and where white space remains through 2026.
Filing growth = 2021 (25 records) → 2024 (22); 2024 is the last year we treat as complete. Top-5 share = the 5 largest assignees ÷ all 1,154 records in scope (CR5), not the ranked leaders only.
This landscape tracks patent filings addressing how refrigerators and refrigerating appliances manage thermal load, food load, cooling load and temperature recovery — the control problem of restoring set-point temperature after a door opening, a fresh food load, or a defrost cycle, without over-consuming energy. The scope spans 1,154 published records filed or published between 2015 and the 2026 cut-off, covering refrigeration hardware, compressor and pump control, and the electronic control layer that governs recovery behaviour.
Because publication trails filing by roughly 18 months, the most recent one or two years in any trend chart will always look thinner than they eventually turn out to be. Family-level counts, not raw document counts, are used throughout so that multi-jurisdiction filing and continuation practice do not inflate any one applicant's apparent footprint.
Two views of the same 1,154-record dataset: how filing activity has moved year over year, and how it splits across the IPC subclasses that appliance and refrigeration engineers actually work in.
Annual filings rose from 28 records in 2017 to a peak of 49 in 2022, then eased — the 2021-to-2024 comparison shows 25 down to 22 records, a 12% decline over that span. Treat 2025 and 2026 as undercounted rather than as evidence of a further drop, since publication lag has not yet caught up with those filing years.
Publication lags filing by roughly 18 months, so 2025 onwards are still filling in. Growth rates on this page therefore end at 2024; running them to the last bar would understate the field.
F25B (refrigeration and heat pumps) and F25D (refrigerators and cooling) each cover more than 40% of the 1,154 records, confirming that most of this landscape is still filed as core refrigeration-cycle hardware rather than as a standalone control discipline. F24F and F04B pick up adjacent air-conditioning and pump mechanics, while the explicitly control-oriented G05D class sits at only 3.2% of records — a signal that the control logic itself is comparatively under-claimed relative to the mechanical systems it governs.
Shares are the percentage of the 1,154 records in scope. A patent can carry several IPC classes, so the shares add up to more than 100%.
This page is one run against one query. Ask Eureka your own question about refrigerator food load and cooling recovery control patent landscape and every answer comes back with the patent numbers behind it.
Try EurekaA refrigeration system includes a first refrigerator having a first cooling load at a first temperature and a second refrigerator having a second cooling load at a second temperature. A thermal coupling between the two refrigerators shares thermal load between them, restricted to maintain a defined temperature difference. The cryopump variant couples a first refrigerator's initial stage to a second refrigerator's cold end under the same temperature-difference restriction.Filed by Brooks Automation; published 2012-02-02.


| # | Publication no. | Patent title | Citations |
|---|---|---|---|
| 1 | US5317878A | Cryogenic cooling apparatus | 128 |
| 2 | US6332323B1 | Heat transfer apparatus and method employing active regenerative cycle | 123 |
| 3 | US4408463A | Wheel-type magnetic refrigerator | 114 |
| 4 | US4953366A | Acoustic cryocooler | 111 |
| 5 | US6877325B1 | Electrocaloric device and thermal transfer systems employing the same | 109 |
| 6 | US4303820A | Capacitative apparatus for thawing frozen food in a refrigeration appliance | 91 |
| 7 | JP2004111581A | Superconducting magnet unit | 86 |
| 8 | US5165243A | Compact acoustic refrigerator | 84 |
| 9 | US6084320A | Structure of linear compressor | 82 |
| 10 | US4748820A | Refrigeration system | 80 |
Citation counts reward older filings simply for having been in circulation longer; read them as a signal of technical influence on later filings, not as a ranking of current commercial relevance.
Each row carries its publication number; clicking a row searches Eureka by that number.
When you want the answer in the next five minutes.
The agent works the prompt against patents and technical literature, citing every source.
Run your analysis now →When it has to run inside your own pipeline.
Patent search, landscape analysis and assignee resolution as MCP tools. Drop them into any agent framework, or call REST directly.
Browse MCP servers →Three figures worth weighing before drafting a claim in this space.
The single leader holds 66 families and the top 5 combined account for 21.1% of all 1,154 records in scope — meaningful concentration, but nowhere near a monopoly. The remaining ranked leaders and the long tail behind the top 10 (32.0% combined) leave room for a differentiated entrant.
Filings ran from 28 in 2017 to a peak of 49 in 2022, then the 2021-to-2024 window shows a 12% pullback (25 to 22 records). That is a real signal for a maturing filing cycle, not a collapsing one — recent years remain undercounted due to publication lag.
F25B and F25D dominate as core refrigeration hardware classes, each above 40% of the 1,154 records, while G05D — control of non-electric variables — sits at just 3.2%. That gap suggests the algorithmic recovery-control layer is less crowded than the mechanical systems around it.
Japan accounts for 454 records and South Korea 178, ahead of China's 173 and the United States' 119 — a reminder that this is predominantly an Asian-manufacturer filing pattern, with EPO and PCT routes used more sparingly.
Eureka can read the same corpus for gaps instead of for coverage: under-claimed branches adjacent to refrigerator food load and cooling recovery control patent landscape, with the prior art for and against each one.
The dataset points to a few concrete follow-ups depending on what you are trying to decide.
With G05D at only 3.2% of the 1,154 records against F25B and F25D each above 40%, the algorithmic recovery-control layer looks under-claimed relative to the mechanical systems it governs. Worth a closer claim-by-claim read before assuming the space is occupied.
Explore white space in EurekaThe peak year was 2022 at 49 records, with the 2021-to-2024 comparison already down 12%. Because 2025-2026 are still filling in, a firmer read on whether this is genuine cooling or a lag artefact needs another 12-18 months of publications.
Track filing trends in EurekaThe top 5 assignees combined hold 21.1% of all records — enough to study their claim scope directly rather than guess at it from aggregate counts.
Compare assignees in EurekaThe ranked leader in this dataset holds 66 families, and the top 5 assignees combined account for 21.1% of the 1,154 records in scope. That is real concentration at the very top, but it is far from a monopoly — the top 10 combined only reach 32.0% of all records, leaving most of the field spread across a long tail of single- or few-filing entrants. Anyone assessing freedom to operate should look at the leader's specific claim scope rather than assume broad blocking coverage across the whole category.
Filing activity rose from 28 records in 2017 to a peak of 49 in 2022, but the most recent complete comparison — 2021 to 2024 — shows a 12% decline, from 25 down to 22 records. That is the honest read on the trend as it stands; 2025 and 2026 counts are still artificially low because publication lags actual filing by roughly 18 months, so it is too early to call this a sustained downturn. A clearer picture will only emerge once those later years finish publishing.
F25B (refrigeration and heat pumps) and F25D (refrigerators and cooling) are the two dominant classes, each covering more than 40% of the 1,154 records in scope. Adjacent mechanical classes — F24F for air conditioning and F04B for positive-displacement pumps — pick up a meaningful secondary share. The explicitly control-oriented class, G05D, covers only 3.2% of records, which suggests the software and control-logic side of temperature recovery is comparatively under-claimed relative to the hardware around it.
Japan is the largest receiving office by a clear margin at 454 records, followed by South Korea at 178 and China at 173. The United States sits at 119, with the EPO and WIPO's PCT route used far less at 56 and 30 respectively. This distribution points to a filing pattern driven largely by Japanese and Korean appliance and refrigeration manufacturers protecting core home markets first.
WO2012016192A2, filed by Brooks Automation, covers a refrigeration system where two refrigerators at different temperatures are thermally coupled to share cooling load, with the coupling restricted to maintain a defined temperature difference between them — including a cryopump variant applying the same principle between refrigerator stages. It is a specific mechanical and thermal-coupling architecture rather than a general claim on load-sharing or temperature recovery, so it constrains multi-refrigerator thermal-coupling designs more than it blocks single-unit food-load or defrost-recovery control schemes. Anyone filing in an adjacent single-unit recovery-control approach should still check its claim boundaries directly rather than assume it covers the whole cooling-load-sharing concept.
Go past this page: query the whole refrigerator food load and cooling recovery control patent landscape corpus yourself, in your own scope.
Every answer comes back with patent numbers you can open.
Disclaimer. This page is generated from Patsnap Eureka data drawn from a limited snapshot of global patent and scientific-literature records, and is provided for general information and reference only.
Patent data carries inherent limitations: recent filings (typically the most recent 18–24 months) are under-counted due to standard publication lag; counts may be reported at either a patent-family or a patent-record basis and are not always directly comparable; classification, applicant-name, and citation data may contain errors, duplicates, or omissions; and the underlying search query defines and constrains the scope shown. As a result, the analysis may be incomplete or inaccurate and may not reflect the full technology landscape.
Nothing on this page constitutes an exhaustive prior-art, novelty, freedom-to-operate, or validity search, nor does it constitute legal, financial, investment, or professional advice, and it should not be relied upon as such. Any patent, commercial, or strategic decision should be verified independently and reviewed with qualified patent, legal, and domain professionals. Patsnap makes no warranties, express or implied, as to the accuracy, completeness, or fitness for any particular purpose of the information presented.
Machine translation. Assignee and organisation names originally recorded in Chinese, Japanese or Korean have been rendered into English by an AI translation step so that the tables stay readable. These renderings are best-effort and may not match a company's registered English name; the original name is what the underlying patent record carries, and it is what any Eureka query launched from this page uses.
Help us improve
Something wrong, out of date, or missing on this page? Tell us and it goes straight to the team that maintains it.
This page