Airflow Distributors for High-Density Rack Thermal Management

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

High-density storage clusters face challenges in thermal management due to high airflow resistance and non-uniform temperature gradients, which affect server reliability and efficiency, and conventional cooling solutions are not optimized for such dense hardware configurations, leading to increased costs and reduced packaging density.

Innovation Solution

An innovative airflow management system that supplies cool air from both sides of a rack using airflow distributors, with perforated designs and rear cooling doors, allowing for efficient airflow distribution and recirculation, and integrating fan systems to manage hot air exhaust, deviating from traditional hot aisle-cold aisle arrangements.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Quantity of substance

If high-density packaging is implemented to decrease storage cost, then packaging density is improved, but airflow resistance increases and thermal management becomes more difficult

Engineering Contradiction:
Improvepackaging densityVSAvoidairflow resistance
Core Design Contradiction:
Quantity of substanceVSObject-affected harmful factors

Solution Approach 1:

The patent transitions from traditional front-to-back single-direction airflow to multi-directional airflow by adding side panels with airflow distributors. This dimensional change allows cooling air to enter from multiple directions (front, back, and sides), effectively managing heat in high-density configurations where horizontal space is constrained.

Inventive Principle:
Principle #17Another dimension (Dimensionality change)

Solution Approach 2:

The cooling system is segmented into multiple independent airflow paths with separate distributors at the front, back, and sides of the rack. Each distributor independently manages airflow to specific drive units, allowing targeted cooling and preventing thermal coupling between adjacent drives in dense configurations.

Inventive Principle:
Principle #1Segmentation

2Quantity of substance

If high-density packaging is implemented to decrease storage cost, then packaging density is improved, but temperature uniformity deteriorates due to high and non-uniform temperature gradients

Engineering Contradiction:
Improvepackaging densityVSAvoidtemperature uniformity
Core Design Contradiction:
Quantity of substanceVSTemperature

Solution Approach 1:

The patent implements local airflow distribution through multiple distributors positioned at different locations (front, back, sides) of the rack. Each distributor provides localized cooling to specific drive units based on their thermal characteristics and position, ensuring uniform temperature distribution across the entire high-density array.

Inventive Principle:
Principle #3Local quality

Solution Approach 2:

By adding vertical and lateral airflow dimensions through side panels and multiple distributors, the system eliminates hot spots and temperature gradients that occur in single-direction cooling, achieving uniform temperature distribution even in high-density configurations.

Inventive Principle:
Principle #17Another dimension (Dimensionality change)

3Ease of manufacture

If conventional cooling solutions are used, then implementation is simple, but they are not optimized for high-density configurations leading to increased costs and reduced efficiency

Engineering Contradiction:
Improveimplementation simplicityVSAvoidcooling efficiency
Core Design Contradiction:
Ease of manufactureVSProductivity

Solution Approach 1:

The airflow distributor design is universal and can be applied to various rack configurations and drive densities. The same basic distributor structure works for different numbers of drives per rack (e.g., 24, 48, or more drives), making the solution scalable and cost-effective for high-density deployments without requiring complete redesign.

Inventive Principle:
Principle #6Universality (Multi-functionality)

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

This solution effectively manages airflow in high-density storage clusters, improving thermal uniformity, reducing costs, and maintaining high packaging density while enhancing server reliability and efficiency by utilizing a novel airflow distribution method.

Implementation Method 1

An innovative airflow management system that supplies cool air from both sides of a rack using airflow distributors

Methodology Applied
Scientific EffectAirflow distribution:

Implementation Method 2

integrating fan systems to manage hot air exhaust

Methodology Applied
Scientific EffectForced convection: Forced Convection

Implementation Method 3

The number of high performance electronic components such as high performance processors packaged inside servers has steadily increased, thereby increasing the amount of heat generated and dissipated

Methodology Applied
Scientific EffectThermal conduction: Conduction (thermal)

Implementation Method 4

cooling airflow management method

Methodology Applied
Scientific EffectConvection: Convection

Data Source

PatentUS11533826B2Air cooling system for component high dense clusters
Publication Date: 2022.12.20 BAIDU USA LLC
  • US11533826B2 patent drawing
  • US11533826B2 patent drawing
  • US11533826B2 patent drawing

AI summary

Cooling systems of one or more electronic racks in a cluster or point of deliver (PoD) are disclosed. A data center system includes an array of electronic racks. Each electronic rack contains a number of server chassis. The system further includes a number of rear cooling doors respectively connected to the electronic racks. Each rear cooling door cools warm/hot air exhaust from a corresponding electronic rack. The system further includes a number of airflow distributors. Each airflow distributor attaches to a side of an electronic rack to supply and distribute a cool/cold airflow to the electronic rack. The distributor either assembled in the PoD or pre-attached with the racks. The system further includes a containment to direct the cooled air towards the airflow distributors.