Automatic Analysis Alarm Scheduling for User-Specific Notifications
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
Existing automatic analysis systems struggle with user notification timing inflexibility, leading to inefficient work schedules due to irregular alarms, as users cannot customize alarm settings based on their authority and operational needs.
Innovation Solution
An automatic analysis system with a control unit that manages alarm settings and notification timing for each user, incorporating a storage unit for consumable data and a display unit to notify alarms at predetermined times, allowing customizable settings.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Reliability
If alarm notification is performed at device operation timing (when measurement is completed or when standby state transition occurs), then device status can be monitored effectively, but user cannot set personalized notification timing and work efficiency decreases
Solution Approach 1:
The alarm notification timing is made dynamic and adjustable rather than fixed. The system allows users to personalize notification timing based on their work schedules and preferences, transforming the static alarm system into a flexible one that adapts to user needs while maintaining reliable device monitoring.
Solution Approach 2:
The notification timing parameter is made changeable through user input. The system accepts user-defined timing parameters and adjusts the alarm notification accordingly, allowing each user to optimize their work efficiency while the system continues to monitor device status reliably.
2Device complexity
If alarm notification timing is fixed at device operation timing, then system operation is simplified, but user cannot customize notification based on their authority and operational needs
Solution Approach 1:
The alarm notification system is segmented into configurable parameters that can be individually adjusted. Instead of a monolithic fixed system, the notification timing is divided into adjustable components that users can personalize according to their specific authority levels and operational requirements.
Solution Approach 2:
The system implements local customization where each user can set their own notification timing preferences. Different users with different authority levels and operational needs receive tailored alarm notifications, allowing the system to adapt to local requirements without increasing overall system complexity.
3Productivity
If number of clinical laboratory technicians decreases and number of measurement specimens increases, then productivity increases, but device users cannot obtain free time to handle irregular alarms
Solution Approach 1:
The system performs preliminary alarm notifications at user-defined times before issues become critical. By notifying users in advance according to their schedules, the system allows technicians to plan their responses efficiently, securing necessary free time while maintaining high measurement throughput.
Solution Approach 2:
The system incorporates user feedback through configurable notification timing. Users can indicate their availability and work patterns, and the system adjusts alarm notifications accordingly. This feedback mechanism ensures that notifications are delivered when users are available, optimizing the balance between productivity and user time management.
Data Source
Figure 1
Figure 2
Figure 3
AI summary
In order to provide an automatic analysis system with which it is possible to select an alarm notification at a prescribed time and select notification content for each user, the present invention has: an automatic analysis device for analyzing a patient sample; a storage unit for storing data pertaining to consumables of the automatic analysis device; a control unit for performing alarm control of the automatic analysis device and controlling data input/output processes into/from the storage unit; a display unit that issues a notification of an alarm upon receiving processing from the control unit; and an alarm setting unit that is capable of setting, for each user, an alarm notification timing.