Bronchoscope Specimen Holder with Needle Guide

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Current bronchoscopy procedures require two practitioners to manage the bronchoscope and specimen container due to the flexibility of the bronchoscope cable, making the process cumbersome and inefficient.

Innovation Solution

A specimen container holding apparatus equipped with a needle guide that allows for the drainage of liquids from the bronchoscope to the specimen container, reducing the dexterity required and minimizing spills, and includes a detachable design for ease of use and cleaning.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Adaptability or versatility

If a flexible bronchoscope cable is used, then the bronchoscope can navigate through airways effectively, but two practitioners are required to handle the bronchoscope and specimen container separately, increasing procedural complexity

Engineering Contradiction:
Improvebronchoscope flexibilityVSAvoidprocedural complexity
Core Design Contradiction:
Adaptability or versatilityVSDevice complexity

Solution Approach 1:

The patent combines the specimen container holder with the bronchoscope into a single integrated apparatus. The container holder is positioned to move with the bronchoscope, allowing one practitioner to control both the bronchoscope and specimen collection simultaneously, thereby reducing procedural complexity while maintaining the flexibility needed for airway navigation

Inventive Principle:
Principle #5Merging (Combining)

Solution Approach 2:

The patent introduces a needle guide as an intermediary component that facilitates the transfer of liquid from the bronchoscope to the specimen container. The needle guide includes openings that receive the needle and guide it into the container, simplifying the drainage process and reducing the skill level required while maintaining effective sample collection

Inventive Principle:
Principle #24Intermediary (Mediator)

2Reliability

If two practitioners are used to handle the bronchoscope and specimen container, then sample collection can be performed, but the procedure becomes cumbersome and less efficient

Engineering Contradiction:
Improvesample collection capabilityVSAvoidprocedural efficiency
Core Design Contradiction:
ReliabilityVSProductivity

Solution Approach 1:

The specimen container holder is integrated with the bronchoscope assembly, allowing a single practitioner to manipulate both components. The holder is positioned adjacent to the bronchoscope tip and moves with it, enabling one-person operation while maintaining reliable sample collection capability

Inventive Principle:
Principle #5Merging (Combining)

Solution Approach 2:

The apparatus is designed with detachable components including the container holder and needle guide that can be separated for cleaning and maintenance. This segmentation allows the integrated design to be achieved while maintaining ease of cleaning and sterilization, thereby improving procedural efficiency without compromising sample collection reliability

Inventive Principle:
Principle #1Segmentation

3Quantity of substance

If liquid drainage from bronchoscope to specimen container is performed manually, then sample transfer can be achieved, but spills are more likely to occur

Engineering Contradiction:
Improveliquid transferVSAvoidspill risk
Core Design Contradiction:
Quantity of substanceVSObject-affected harmful factors

Solution Approach 1:

The needle guide serves as an intermediary device that channels liquid from the bronchoscope needle directly into the specimen container. The guide includes specific openings that receive and direct the needle, creating a controlled drainage path that minimizes spill risk while ensuring complete liquid transfer

Inventive Principle:
Principle #24Intermediary (Mediator)

Solution Approach 2:

The patent replaces manual, uncontrolled liquid transfer with a guided mechanical system. The needle guide provides a structured pathway for the needle, substituting manual dexterity requirements with a mechanical guidance system that reduces spill risk and improves transfer reliability

Inventive Principle:
Principle #28Mechanics substitution (Replace mechanical system)

4Ease of operation

If the specimen container holder is integrated with the bronchoscope, then single-practitioner operation is enabled, but cleaning and maintenance become more challenging

Engineering Contradiction:
Improvesingle-practitioner operationVSAvoidcleaning accessibility
Core Design Contradiction:
Ease of operationVSEase of repair

Solution Approach 1:

The integrated apparatus is designed with detachable segments including the container holder and needle guide that can be separated from the main bronchoscope body. This segmentation enables easy disassembly for thorough cleaning and maintenance while maintaining the integrated functionality during operation, thus resolving the contradiction between ease of operation and ease of cleaning

Inventive Principle:
Principle #1Segmentation

Data Source

PatentUS11660077B2Specimen container holding apparatus
Publication Date: 2023.05.30 BERIM ILYA
  • US11660077B2 patent drawing
  • US11660077B2 patent drawing
  • US11660077B2 patent drawing

AI summary

A specimen container holding apparatus is disclosed. The apparatus is configured to hold a container for receiving liquids from a bronchoscope. The apparatus includes a needle guide with a first and a second opening configured to receive a needle of the bronchoscope. The first and second opening may be disposed on a removable tip of the needle guide. The removable tip may be detachably connected to a removable tip connection point. The apparatus may further include a slide holder configured to hold a slide.