Ceiling Fan Blade Reinforcement and Drop Prevention
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
Conventional ceiling fans suffer from weak blade strength due to stress concentration at reinforcement points, leading to metal fatigue, and often experience blade drop issues due to improper mounting of the blade drop prevention portion.
Innovation Solution
The ceiling fan design incorporates a blade structure with a longer first reinforcement and multiple shorter second reinforcements to distribute stress, and a blade drop prevention mechanism with a locking portion and fixing holes to ensure secure mounting.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Strength
If a reinforcement is provided in the blade, then the strength is improved in the portion where the reinforcement is provided, but the stress concentrates on the portion where the reinforcement is not provided, causing metal fatigue
Solution Approach 1:
The blade is divided into multiple reinforcement portions along its length. Instead of having a single reinforcement, multiple reinforcements are strategically positioned at different locations (near the root, middle, and tip portions) to segment the stress distribution across the blade structure, preventing stress concentration at any single point.
Solution Approach 2:
Different reinforcement structures are applied to different portions of the blade based on local stress requirements. The root portion, middle portion, and tip portion each have reinforcements tailored to their specific structural needs, with varying dimensions and positions to optimize local strength while maintaining overall blade reliability.
2Reliability
If the blade drop prevention portion is fastened together with the blade to the support with screws, then the blade is secured, but the tape used to fix the blade drop prevention portion to the blade may peel off, causing improper mounting
Solution Approach 1:
The blade drop prevention portion is pre-fixed to the blade using tape during the manufacturing process. This preliminary action ensures that the blade drop prevention portion is already in the correct position before the actual assembly, reducing the complexity of the mounting process and ensuring proper alignment when screws are fastened.
Solution Approach 2:
Tape is used as an intermediary element to temporarily hold the blade drop prevention portion to the blade during assembly. This intermediary allows for easy positioning and adjustment before final fastening, simplifying the overall mounting process while ensuring reliable connection.
Data Source
AI summary
A ceiling fan includes blade (11) that is integrally formed of root (12), vane (13), and step (14) for maintaining vane (13) in a state inclined from horizontal. Blade (11) includes bend (16) on upstream side (11c), first reinforcement (17) on upstreamdownstream side (11c)(11b), and a plurality of second reinforcements (18) between bend (16) and first reinforcement (17). First reinforcement length (17a) is longer than second reinforcement length (18a). Further, the ceiling fan includes blade drop prevention portion (37) for locking blade (11) to support (10).