Chuck Run-Out Measurement After Claw Exchange
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
The reliability of chuck grip accuracy checking is compromised due to potential misreading of measured values and variability in measurements when operators manually check the run-out of workpieces after claw exchange in conventional methods.
Innovation Solution
A chuck grip accuracy checking method and device that automates the process by using a movable member with measurement instruments to measure the run-out of a measurement target while the chuck is rotated, ensuring precise measurement of both cylindrical outer and distal end surfaces, thereby reducing operator error and variability.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Reliability
If an operator manually measures run-out of a workpiece after claw exchange, then the measurement can be performed, but the reliability is compromised due to potential misreading and variability
Solution Approach 1:
The patent replaces the manual mechanical measurement process with an automated measurement system. A measurement instrument is mounted on a movable member that can automatically position itself to measure the run-out of the workpiece held by the chuck, eliminating operator involvement and its associated errors.
Solution Approach 2:
The measurement system is designed to autonomously perform the measurement task. The movable member automatically positions the measurement instrument, and the system independently completes the run-out measurement without requiring operator intervention, making the system self-sufficient for this function.
2Reliability
If a movable member with measurement instrument is introduced to automate measurement, then measurement reliability improves, but device complexity increases
Solution Approach 1:
The movable member is designed to perform multiple functions: it can hold the measurement instrument, position itself accurately, and facilitate run-out measurement. This multi-functionality reduces the need for separate dedicated components, thereby limiting the increase in overall system complexity.
Solution Approach 2:
The movable member acts as an intermediary between the measurement instrument and the workpiece. It provides a stable, controllable platform that bridges the gap between the fixed measurement instrument and the rotating workpiece, simplifying the overall measurement architecture.
Data Source
AI summary
A chuck grip accuracy checking method includes a gripping in which the measurement target is gripped on the claws, a moving step, and a measuring step. In the moving step, a movable member provided with a measurement instrument capable of measuring a run-out of the measurement target is moved by driving a movable-member driver to a position at which the measurement instrument can measure a run-out of the measurement target. In the measuring step, a run-out of the measurement target is measured by the measurement instrument, while the chuck is being rotated by driving a rotation driver.


