Closed Cooling Loop with Dielectric Fluid for High-Power Rack Heat Dissipation

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Current liquid cooling systems for data centers are inefficient and costly due to high water requirements, pressure and flow demands, and structural weight issues, especially in high-power computing environments where heat dissipation exceeds 50-100 kW per rack.

Innovation Solution

A closed cooling loop system using a dielectric fluid that circulates through a network of tubing connected to processors, allowing for phase-change cooling with a lower flow rate and reduced system size, weight, and cost, while maintaining efficient heat transfer and compatibility with various environments.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Temperature

If conventional liquid cooling systems use water and copper cold plates, then heat dissipation can be achieved, but the system requires high water flow rates and creates excessive structural weight

Engineering Contradiction:
Improveheat dissipation capabilityVSAvoidsystem weight
Core Design Contradiction:
TemperatureVSWeight of stationary object

Solution Approach 1:

The patent changes the physical parameters of the cooling system by using dielectric fluid instead of water, enabling operation at lower flow rates (e.g., 10-50 mL/min vs. traditional higher rates) while maintaining effective heat dissipation from processors in high-power computing racks

Inventive Principle:
Principle #35Parameter changes

Solution Approach 2:

The system employs composite construction with aluminum cold plates instead of traditional copper, combined with dielectric fluid, creating a lighter yet thermally effective cooling system that reduces overall weight while maintaining heat transfer efficiency

Inventive Principle:
Principle #40Composite materials

2Temperature

If conventional liquid cooling systems increase water flow rate to cool high-power racks, then heat dissipation improves, but system complexity and cost increase

Engineering Contradiction:
Improveheat dissipation capabilityVSAvoidsystem complexity
Core Design Contradiction:
TemperatureVSDevice complexity

Solution Approach 1:

The patent reduces the operating flow rate parameter to 10-50 mL/min, which simplifies the pumping system requirements, reduces conduit sizing, and lowers overall system complexity while effectively cooling high-power computing racks that traditionally required complex high-flow systems

Inventive Principle:
Principle #35Parameter changes

3Temperature

If conventional liquid cooling systems use copper components, then heat transfer efficiency is maintained, but corrosion and inter-metallic compatibility issues arise

Engineering Contradiction:
Improveheat transfer efficiencyVSAvoidcorrosion resistance
Core Design Contradiction:
TemperatureVSReliability

Solution Approach 1:

The patent changes the material parameter from copper to aluminum for cold plates, combined with using dielectric fluid instead of water, which eliminates corrosion and inter-metallic compatibility issues while maintaining effective heat transfer efficiency through the aluminum-dielectric fluid interface

Inventive Principle:
Principle #35Parameter changes

Solution Approach 2:

The dielectric fluid serves as an intermediary cooling medium that is chemically compatible with aluminum components, preventing direct corrosive interaction between coolant and metal surfaces while still enabling efficient heat extraction from processors

Inventive Principle:
Principle #24Intermediary (Mediator)

4Temperature

If conventional liquid cooling systems are used for high-power racks, then cooling capacity is achieved, but continuous monitoring and correction of fluid properties are required

Engineering Contradiction:
Improvecooling capacityVSAvoidmaintenance requirements
Core Design Contradiction:
TemperatureVSEase of operation

Solution Approach 1:

The dielectric fluid in the closed-loop system is self-sustaining with no requirement for continuous monitoring or correction of fluid properties such as pH, conductivity, or contamination levels, eliminating the operational burden of maintaining coolant quality while providing reliable cooling capacity

Inventive Principle:
Principle #25Self-service

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The closed cooling loop system achieves high thermal performance with lower flow rates, reduced system size and weight, and increased reliability, enabling efficient heat management in high-power computing environments without the need for continuous monitoring and correction of fluid properties.

Implementation Method 1

allowing for phase-change cooling

Methodology Applied
Scientific EffectPhase change: Phase Change

Implementation Method 2

a liquid portion of the dielectric fluid is to evaporate from the processor heat absorbed by the dielectric fluid

Methodology Applied
Scientific EffectEvaporation: Evaporation

Implementation Method 3

a vapor portion of the dielectric fluid is to condense from the heat removed by the coolant flow

Methodology Applied
Scientific EffectCondensation: Condensation

Data Source

PatentUS11026351B2Computing apparatus with closed cooling loop
Publication Date: 2021.06.01 INTEL CORP
  • US11026351B2 patent drawing
  • US11026351B2 patent drawing
  • US11026351B2 patent drawing

AI summary

The present disclosure describes embodiments of apparatuses and methods related to a computing apparatus with a closed cooling loop thermally coupled to one or more processors disposed on a circuit board of the computing apparatus. The closed cooling loop circulates a dielectric fluid to absorb heat from the processor. A portion of the dielectric fluid is evaporated from the processor heat absorbed by the dielectric fluid. A heat exchanger is coupled to the circuit board and thermally coupled to the closed cooling loop. The heat exchanger is to include a coolant flow to remove heat from the dielectric fluid circulated through the portion of the closed cooling loop thermally coupled to the heat exchanger. A vapor portion of the dielectric fluid is condensed from the heat removed by the coolant flow. Other embodiments may be described and/or claimed.