Problem
Turbulent air flow and high relative humidity in semiconductor processing environments can lead to contamination and oxidation of wafers, resulting in defects and reduced manufacturing yield.
Innovation Solution
A closed gas circulation system with a sealed plenum, circulation fans, air-flow rectifier, and vacuum pumps is implemented to provide a collimated downflow of gas, reducing turbulence and controlling humidity and oxygen levels, thereby minimizing contamination and oxidation.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Object-affected harmful factors
If a closed gas circulation system with sealed plenum is implemented, then contamination collection efficiency is enhanced and wafer oxidation is reduced, but device complexity increases
Solution Approach 1:
The gas circulation system is segmented into distinct functional zones: a sealed plenum chamber for gas storage and pressure regulation, a distribution manifold for even gas delivery, and a chamber environment control system. This segmentation allows each component to be optimized independently for its specific function while collectively reducing wafer contamination.
Solution Approach 2:
The sealed plenum acts as an intermediary component between the external environment and the wafer processing chamber. It provides a buffer zone that regulates gas flow and maintains stable pressure conditions, preventing direct exposure of wafers to turbulent or contaminated air flows while simplifying the overall system architecture.
2Reliability
If circulation fans and vacuum pumps are used to control gas flow, then humidity and oxygen levels are controlled, but energy consumption increases
Solution Approach 1:
The circulation fans operate continuously to maintain steady gas flow patterns and stable environmental conditions within the chamber. This continuous operation ensures consistent humidity and oxygen level control, preventing defects while optimizing energy efficiency through sustained, low-power operation rather than intermittent high-power cycles.
Solution Approach 2:
The system dynamically adjusts gas flow parameters and circulation rates based on real-time environmental monitoring. By changing flow parameters only when necessary to maintain target humidity and oxygen levels, the system achieves reliable environmental control while minimizing energy consumption of the circulation components.
3Manufacturing precision
If a collimated downflow of gas is implemented, then turbulence is reduced and contamination is minimized, but manufacturing complexity increases
Solution Approach 1:
The gas distribution system creates locally optimized flow patterns with collimated downflow directly over the wafer processing areas while allowing different flow characteristics in other chamber regions. This local quality approach minimizes turbulence and contamination at critical locations without requiring complex flow control throughout the entire chamber, simplifying the overall system design.
Applied Scientific Principles
This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.
Function Achieved in This Case
This solution enhances contamination collection efficiency, reduces wafer defects, increases yield, and improves productivity by maintaining precise environmental conditions within the processing chamber.
Implementation Method 1
A closed gas circulation system with a sealed plenum, circulation fans, air-flow rectifier, and vacuum pumps is implemented to provide a collimated downflow of gas, reducing turbulence
Implementation Method 2
A closed gas circulation system with a sealed plenum, circulation fans, air-flow rectifier, and vacuum pumps is implemented to provide a collimated downflow of gas, reducing turbulence and controlling humidity and oxygen levels, thereby minimizing contamination and oxidation.
Implementation Method 3
A closed gas circulation system with a sealed plenum, circulation fans, air-flow rectifier, and vacuum pumps is implemented to provide a collimated downflow of gas
Data Source
AI summary
A closed gas circulation system may include a sealed plenum, circulation fans, and a fan filter unit (FFU) inlet to contain, filter, condition, and re-circulate a gas through a chamber of an interface tool. The gas provided to the chamber is maintained in a conditioned environment in the closed gas circulation system as opposed to introducing external air into the chamber through the FFU inlet. This enables precise control over the relative humidity and oxygen concentration of the gas used in the chamber, which reduces the oxidation of semiconductor wafers that are transferred through the chamber. The closed gas circulation system may also include an air-flow rectifier, a return vent, and one or more vacuum pumps to form a downflow of collimated gas in the chamber and to automatically control the feed-forward pressure and flow of gas through the chamber and the sealed plenum.