Problem

Existing air conditioners face inefficiencies in cooling the PCB due to high-temperature external air blown by the fan and motor assembly, which hampers effective heat dissipation.

Innovation Solution

The air conditioner incorporates a control box with a cooling module that utilizes both refrigerant cooling and air cooling, featuring a refrigerant pipe, heat transfer plates, and a heat absorbing plate to create an air circulation passage for efficient heat exchange, with a circulating fan directing cooled air to high and low heat generation components on the PCB.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Device complexity

If external air is used for cooling the PCB, then the cooling system is simple, but the cooling efficiency deteriorates when external air temperature is high

Engineering Contradiction:
Improvecooling system complexityVSAvoidPCB cooling efficiency
Core Design Contradiction:
Device complexityVSTemperature

Solution Approach 1:

The cooling system is segmented into two independent parts: a refrigerant cooling path for high-heat components and an air cooling path for low-heat components. This segmentation allows each cooling method to be optimized for its specific function, resolving the contradiction by maintaining system simplicity while improving overall cooling efficiency through targeted approaches.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

Different cooling methods are applied to different regions of the PCB based on heat generation characteristics. High-heat components receive refrigerant cooling while low-heat components receive air cooling. This local quality approach ensures optimal cooling efficiency for each component type without requiring a completely complex system redesign.

Inventive Principle:
Principle #3Local quality

2Temperature

If refrigerant cooling is applied to all components, then cooling efficiency is maximized, but device complexity and power consumption increase

Engineering Contradiction:
Improvecooling efficiencyVSAvoidcooling system complexity
Core Design Contradiction:
TemperatureVSDevice complexity

Solution Approach 1:

Refrigerant cooling is applied only to high-heat generating components on the PCB, while standard air cooling suffices for low-heat components. This selective application of refrigerant cooling maximizes cooling efficiency where needed while avoiding the increased complexity and power consumption that would result from applying refrigerant cooling to all components.

Inventive Principle:
Principle #3Local quality

Solution Approach 2:

Instead of applying full refrigerant cooling system to all components, the invention uses partial action by targeting only the high-heat components that require enhanced cooling. This partial application achieves sufficient cooling efficiency while maintaining simpler device architecture and lower power consumption.

Inventive Principle:
Principle #16Partial or excessive action

3Stability of the object's composition

If uniform cooling is applied to all PCB components, then temperature distribution is balanced, but power consumption increases

Engineering Contradiction:
Improvetemperature distribution uniformityVSAvoidpower consumption
Core Design Contradiction:
Stability of the object's compositionVSUse of energy by moving object

Solution Approach 1:

The cooling system applies different cooling intensities to different regions of the PCB based on local heat generation characteristics. High-heat components receive intensive refrigerant cooling while low-heat components receive milder air cooling. This local quality approach maintains adequate temperature distribution balance while significantly reducing overall power consumption compared to uniform high-intensity cooling.

Inventive Principle:
Principle #3Local quality

Solution Approach 2:

The invention uses partial action by applying enhanced refrigerant cooling only to high-heat components rather than uniformly to all components. This selective approach maintains sufficient temperature balance where needed while avoiding excessive power consumption in regions where standard air cooling is adequate.

Inventive Principle:
Principle #16Partial or excessive action

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

This solution enables quick and uniform cooling of the PCB and control box interior, minimizing power consumption loss by leveraging refrigerant cooling for high heat components and air cooling for low heat components, regardless of external temperature conditions.

Implementation Method 1

a cooling module for making a first electric component of the plurality of electric components to heat exchange with refrigerant

Methodology Applied
Scientific EffectHeat exchange: Heat Exchanger

Implementation Method 2

a heat transfer plate in contact with the refrigerant pipe and the first electric component

Methodology Applied
Scientific EffectThermal conduction: Conduction (thermal)

Implementation Method 3

a heat absorbing plate in contact with the heat transfer plate for heat exchange with the air in the air circulation passage

Methodology Applied
Scientific EffectConvection: Convection

Data Source

PatentEP3017255B1Air conditioner
Publication Date: 2019.09.18 LG ELECTRONICS INC
  • EP3017255B1 patent drawingFigure 1~2
  • EP3017255B1 patent drawingFigure 3~4
  • EP3017255B1 patent drawingFigure 5

AI summary

Disclosed in an air conditioner including a control box having a space formed therein, a PCB arranged to form an air circulation passage in the space, the PCB having a plurality of electric components mounted thereto, a cooling module for making a first electric component of the plurality of electric components to heat exchange with refrigerant, and a circulating fan arranged in the air circulation passage to make air to flow to a second electric component of the plurality of electric components after cooled by the cooling module, thereby dissipating heat from an inside of the control box with a mixed cooling system of a refrigerant cooling system and an air cooling system, efficiently.