Problem
Factory automation controllers face storage capacity limitations, leading to log data loss when the external storage device runs out of space, requiring frequent replacements and potential delays in replacing the device.
Innovation Solution
A control apparatus with a buffer monitoring unit that alerts users before the buffer runs out of free space, allowing for timely replacement of the external storage device, and includes an internal storage option to temporarily store log data during device replacement.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Quantity of substance
If the external storage device is used to store log data, then the storage capacity is extended, but the buffer runs out of free space quickly requiring frequent replacements
Solution Approach 1:
The monitoring unit performs preliminary action by detecting the free space of the buffer in advance and generating a warning signal before the buffer becomes full. This allows the user to replace the external storage device before log data loss occurs, resolving the contradiction by providing advance notice without requiring immediate replacement.
2Quantity of substance
If the buffer size is increased, then more log data can be stored during replacement, but the device complexity increases
Solution Approach 1:
The monitoring unit provides feedback about the buffer's free space status to the user through a warning signal. This feedback mechanism allows the system to maintain a relatively small buffer while still preventing data loss, as users are notified in advance when replacement is needed, avoiding the need for a large buffer and thus reducing device complexity.
3Productivity
If the user waits until the buffer is full to replace the external storage device, then replacement frequency is reduced, but log data is lost
Solution Approach 1:
The monitoring unit performs preliminary detection of buffer free space and generates a warning signal before the buffer becomes full. This preliminary action enables the user to replace the external storage device at an optimal time - not too early (which would increase replacement frequency) and not too late (which would cause data loss), thus resolving the contradiction between replacement frequency and data integrity.
Data Source
AI summary
A technique is desired that can output a warning to a user before a buffer of a controller runs out of a free space. A control apparatus includes a buffer for buffering log data sequentially generated, an interface unit connectable with an external storage device, a writing unit for sequentially reading the log data buffered to the buffer and sequentially writing the log data to the external storage device while the external storage device is connected to the interface unit, a monitoring unit for monitoring a free space of the buffer, and a warning unit for outputting a warning upon the free space falling below a prescribed value.