Coolant Liquid Manifold for IT Equipment Cooling
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
Existing IT enclosures face challenges with discrete cold plate loops that require numerous connections to a rack-level cooling manifold, leading to increased complexity and space requirements as more components need cooling, limiting efficiency and scalability.
Innovation Solution
A modular IT enclosure design incorporating a coolant liquid manifold with quick disconnect fittings and a fluid splitter to distribute and manage cooling fluid efficiently across multiple cold plates, reducing the need for discrete loops and simplifying assembly and servicing.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Adaptability or versatility
If discrete cold plate loops are used to cool IT components, then each component can be cooled individually, but the number of connections to the rack-level cooling manifold increases significantly, leading to increased system complexity and space requirements
Solution Approach 1:
The patent combines multiple discrete cold plate loops into a single integrated manifold assembly where multiple cold plates share common fluid distribution pathways. This merging reduces the total number of connections required at the rack-level cooling manifold while maintaining individual cooling capability for each IT component.
Solution Approach 2:
The manifold assembly is designed as a universal interface that can accommodate multiple different cold plates serving various IT components (processors, GPUs, storage devices) through standardized connection points. This multi-functional design allows a single manifold structure to handle cooling for diverse components without requiring separate dedicated connections for each.
2Reliability
If discrete cold plate loops with multiple connections are implemented, then comprehensive cooling coverage is achieved, but the space requirements within the IT enclosure increase
Solution Approach 1:
The manifold assembly is designed with a compact nested structure where fluid distribution channels are integrated within the manifold body itself rather than requiring separate external tubing for each connection. This nesting approach consolidates the cooling infrastructure into a space-efficient configuration that maintains comprehensive cooling coverage while minimizing the volume occupied within the IT enclosure.
3Adaptability or versatility
If numerous discrete connections are made to the rack-level cooling manifold, then each component receives dedicated cooling, but assembly and servicing become more difficult
Solution Approach 1:
The cooling system is segmented into modular components where the manifold assembly serves as a self-contained unit with integrated cold plates. This segmentation allows the entire manifold assembly to be pre-assembled and tested as a single module, then installed as one unit rather than requiring assembly of numerous individual connections, significantly easing both manufacturing and servicing operations.
Applied Scientific Principles
This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.
Function Achieved in This Case
The coolant liquid manifold enables flexible and efficient distribution of cooling fluid to various IT components, reducing complexity, minimizing space requirements, and enhancing scalability by consolidating connections and allowing for tailored fluid flow to each component.
Implementation Method 1
a chilled fluid is passed through conduits internal to the cold plate to remove heat from that component
Data Source
AI summary
An information technology equipment enclosure comprises a plurality of IT components, cold plates disposed over at least two of the IT components, and a cooling fluid manifold disposed within the IT equipment enclosure. The coolant liquid manifold has multiple input connectors and multiple output connectors. Each of the cold plates are coupled to the cooling fluid manifold using a coolant line attached to one of the input connectors and a coolant line attached to one of the output connectors. An input cooling liquid line couples the coolant liquid manifold to an output of an external liquid cooling system, and an output liquid line couples the coolant liquid manifold to an input of the external liquid cooling system. The coolant liquid manifold is configured to receive cooling fluid from the external liquid cooling system and to distribute the cooling fluid to all of the cold plates via the input connectors.