DIMM Heatsink Pedestals With Sliding TIM Pads for Dense Memory Cooling

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

The increasing thermal design power and number of Dual In-line Memory Modules (DIMMs) pose challenges in maintaining temperatures within thermal specification limits, particularly for RDIMMs, MRDIMMs, and SIMMs, with existing cooling solutions like increased air flow velocity and liquid cooling being inadequate.

Innovation Solution

The implementation of heatsinks with thermally conductive fins and pedestals, combined with sliding thermal interface material (TIM) pads, enhances heat dissipation and distribution without increasing air flow velocity or reducing air inlet temperature, and includes features like vapor chambers for improved cooling efficiency.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Temperature

If common cooling solutions (increased air flow velocity, reduced air temperature, liquid cooling) are used, then cooling performance is improved, but device complexity and manufacturing difficulty increase

Engineering Contradiction:
ImproveDIMM temperatureVSAvoidcooling system complexity
Core Design Contradiction:
TemperatureVSDevice complexity

Solution Approach 1:

The heatsink is divided into multiple independent pedestals (first pedestal, second pedestal, third pedestal, fourth pedestal) that can be separately positioned and adjusted. Each pedestal can be independently adjusted to make contact with the corresponding DIMM module, allowing for modular assembly and easier manufacturing while maintaining effective thermal contact with all heat-generating components.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

The pedestals are designed with adjustable positioning capabilities, allowing them to be moved between different positions to accommodate variations in DIMM module placement and thermal contact requirements. This dynamic adjustment feature enables the cooling system to adapt to different configurations without requiring complex custom-designed components for each scenario.

Inventive Principle:
Principle #15Dynamics

2Temperature

If heat spreaders and improved air distribution systems are added, then cooling efficiency is enhanced, but manufacturing feasibility and field serviceability become more difficult

Engineering Contradiction:
ImproveDIMM temperatureVSAvoidmanufacturing feasibility
Core Design Contradiction:
TemperatureVSEase of manufacture

Solution Approach 1:

The heatsink structure serves multiple functions simultaneously: the pedestals provide both structural support for the DIMM modules and thermal conduction paths for heat dissipation. The same components that position the modules also serve as heat sinks, eliminating the need for separate mounting structures and simplifying manufacturing while maintaining cooling effectiveness.

Inventive Principle:
Principle #6Universality (Multi-functionality)

Solution Approach 2:

The cooling function and structural support function are merged into a single integrated heatsink assembly. The pedestals simultaneously provide mechanical positioning and thermal management, reducing the total number of components and simplifying both manufacturing and field serviceability compared to separate cooling and support structures.

Inventive Principle:
Principle #5Merging (Combining)

3Reliability

If more pedestals and thermal contact points are added, then thermal connection is improved, but device complexity increases

Engineering Contradiction:
Improvethermal connection reliabilityVSAvoidheatsink structure complexity
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

Thermal contact is optimized at specific localized points where the pedestals make direct contact with the DIMM modules. Rather than requiring broad surface contact throughout the entire structure, the design concentrates thermal conduction at the critical interface points between pedestals and modules, achieving reliable thermal connection with a simpler structure.

Inventive Principle:
Principle #3Local quality

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The proposed system achieves a temperature reduction of 5°C to 15°C cooler at the same incoming air flow rate and temperature, balancing field serviceability and manufacturing feasibility.

Implementation Method 1

The plurality of thermally conductive fins extend in a first direction away from the base. The plurality of pedestals extend in a second direction away from the base and opposite the first direction.

Methodology Applied
Scientific EffectThermal conduction: Conduction (thermal)

Implementation Method 2

Common cooling solutions include increasing the approaching air flow velocity, reducing the approaching air temperature for air cooling

Methodology Applied
Scientific EffectConvection: Convection

Implementation Method 3

The sliding TIM pads provide thermal connections between the plurality of pedestals and an adjacent in-line memory module when the plurality of pedestals contact the sliding TIM pads

Methodology Applied
Scientific EffectThermal conduction: Conduction (thermal)

Data Source

PatentEP4675396A1Heatsinks for in-line memory modules
Publication Date: 2026.01.07 GOOGLE LLC
  • EP4675396A1 patent drawingFigure 1
  • EP4675396A1 patent drawingFigure 2
  • EP4675396A1 patent drawingFigure 3

AI summary

A system for cooling a plurality of in-line memory modules includes sliding thermal interface material ("TIM") pads and a heatsink thermally coupled to the in-line memory modules through the sliding TIM pads. The heatsink further includes a base, a plurality of thermally conductive fins, and a plurality of pedestals. The base extends in a plane. The plurality of thermally conductive fins extend in a first direction away from the base. The plurality of pedestals extend in a second direction away from the base and opposite the first direction. The sliding TIM pads are positioned between each of the plurality of pedestals and an adjacent in-line memory module. The plurality of pedestals further include a first leg and a second leg. The first and second legs are configured to move between a first position and a second position.