Dipole Matched Filter for MRI Signal Dropout

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Standard magnetic resonance imaging sequences often exhibit undesirable signal dropouts when imaging large local dipoles, due to inadequate existing systems.

Innovation Solution

A dipole matched filter is applied in k-space to suppress background signals, using a secular dipole field pattern that is scale invariant and has a high-pass property, effectively enhancing the visibility of local dipole field perturbations by combining with sequences like SWIFT and post-processing techniques.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Reliability

If standard magnetic resonance imaging sequences are used to image large local dipoles, then the imaging process is simple and fast, but signal dropout artifacts occur reducing image quality

Engineering Contradiction:
Improveimage qualityVSAvoidimaging sequence complexity
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

A dipole matched filter is designed and prepared in advance based on the expected dipole characteristics (size, orientation, location). This filter is then applied to the k-space data before image reconstruction, preventing signal dropout artifacts from occurring in the final image without requiring complex modifications to the imaging sequence itself

Inventive Principle:
Principle #10Preliminary action

Solution Approach 2:

The dipole matched filter serves as an intermediary processing step between data acquisition and image reconstruction. It operates in k-space to selectively enhance dipole signals while suppressing background, resolving the contradiction by adding a intermediate processing layer rather than modifying the core imaging sequence

Inventive Principle:
Principle #24Intermediary (Mediator)

2Reliability

If a dipole matched filter is applied in k-space to suppress background signals, then signal-to-background ratio is improved, but processing complexity increases

Engineering Contradiction:
Improvesignal-to-background ratioVSAvoidprocessing complexity
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

The solution replaces complex spatial domain filtering operations with simpler k-space domain multiplication. By transforming the filtering operation to k-space, the complex convolution operation becomes a simple element-wise multiplication, significantly reducing computational complexity while maintaining the signal-to-background enhancement effect

Inventive Principle:
Principle #28Mechanics substitution (Replace mechanical system)

Solution Approach 2:

The filter design uses parameterization based on dipole characteristics (size, orientation, location) to create a scalable solution. Once the filter is designed for a specific dipole configuration, it can be applied repeatedly with minimal additional processing, reducing the effective complexity for multiple applications

Inventive Principle:
Principle #35Parameter changes

Data Source

PatentUS8798340B2Dipole matched filter for MRI
Publication Date: 2014.08.05 REGENTS OF THE UNIVERSITY OF MINNESOTA
  • US8798340B2 patent drawing
  • US8798340B2 patent drawing

AI summary

A method includes receiving k-space data corresponding to magnetic resonance data for a subject and selecting a template for analysis. In addition, the method includes generating an image using the k-space data and using the template.