Problem
In tumble dryers, lint accumulates in areas between the drum and heat exchanger, particularly in the duct where the air direction changes from vertical to horizontal, leading to reduced efficiency due to lint deposition and impaired heat transfer, despite existing lint filters.
Innovation Solution
A tray is positioned between the duct and heat exchanger, acting as a diverter and lint trap, with a removable grating and grip for easy handling, ensuring all lint is collected and can be disposed of without manual intervention.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Reliability
If a lint filter is installed to trap lint, then lint removal efficiency is improved, but lint still accumulates in the duct between the drum and heat exchanger
Solution Approach 1:
A tray is introduced as an intermediary component between the duct and heat exchanger. This tray serves as a secondary collection point that intercepts lint carried by the process air stream after it passes through the primary lint filter but before it reaches the heat exchanger, preventing lint accumulation in the duct.
Solution Approach 2:
The lint collection function is segmented into two separate locations: the primary lint filter and the secondary tray. This segmentation allows each component to address specific accumulation zones, with the tray specifically targeting the duct area between the drum and heat exchanger where the process air stream changes direction.
2Stability of the object's composition
If the tray is fixed to the heat exchanger, then structural stability is improved, but lint disposal requires manual intervention
Solution Approach 1:
The tray is segmented into a stationary mounting structure (secured to the heat exchanger) and a removable grating component. The grating can be easily removed from the stationary tray body, allowing lint disposal without manual intervention while maintaining the structural stability of the overall assembly.
Solution Approach 2:
The grating is extracted as a separate, removable component from the tray assembly. This allows the grating to be easily taken out for lint disposal and then reinserted, combining the benefits of structural stability during operation with ease of maintenance during cleaning.
3Ease of repair
If the tray is designed with a grating for easy lint removal, then maintenance ease is improved, but structural complexity increases
Solution Approach 1:
The tray incorporates a grating structure that functions as a porous or open-mesh component. This grating design allows lint to be easily accessed and removed while maintaining a relatively simple overall tray structure. The grating acts as both a structural element and a functional lint access point.
Applied Scientific Principles
This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.
Function Achieved in This Case
The tray effectively traps and allows for easy removal of lint, enhancing the operational efficiency and cleanliness of the tumble dryer by preventing lint buildup and maintaining heat transfer efficiency.
Implementation Method 1
a tray (2) which is open in the horizontal direction and counter to the vertically falling direction is arranged between the duct and the heat exchanger which is embodied as a diverter for the process air stream
Implementation Method 2
a heat exchanger (1) through which a process air stream is able to flow in a horizontal direction (3)
Implementation Method 3
a lint filter is arranged which traps a large part of the lint arising during the drying process
Implementation Method 4
Such lint is deposited with condensing water vapor in the vicinity of the heat exchanger
Data Source
AI summary
A tumble dryer is provided having a heat exchanger through which a process-air stream flows in a first direction and a first duct which is arranged in fluid communication with the heat exchanger through which a process-air stream flows in a second direction and in which a lint filter is disposed. A tray having its own lint filter is removably attached to the heat exchanger and arranged between the duct and the heat exchanger.