Problem
Existing techniques for testing lighting equipment performance often result in incorrect measurements due to issues like the measuring device being hidden or facing the wrong direction, leading to abnormal values.
Innovation Solution
An electromagnetic wave measuring device comprising a measurement data receiving unit, an abnormal value detecting unit, and a display controlling unit that receives data from multiple positions, detects abnormal values, and displays the position of measurement on a screen, along with relative positional relationships, allowing for effective highlighting and remeasurement.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Area of stationary object
If measurement is performed at multiple positions, then measurement coverage is improved, but abnormal values due to incorrect positioning increase
Solution Approach 1:
The system displays the measured position on a screen and provides feedback when an abnormal value is detected. The operator can see where the measurement was taken and whether it is within the correct range, allowing them to adjust their positioning and remeasure if necessary. This feedback loop prevents incorrect measurements from being accepted and ensures measurement accuracy across the expanded measurement area.
2Adaptability or versatility
If operator manually positions measuring device, then measurement flexibility is improved, but positioning accuracy deteriorates
Solution Approach 1:
The system replaces manual mechanical positioning judgment with automated position detection technology. A position detection device automatically determines the measured position, and the control device displays this position on a screen. This substitution of mechanical judgment with automated detection maintains measurement flexibility while significantly improving positioning accuracy.
3Productivity
If abnormal values are not detected, then measurement process speed is improved, but data reliability deteriorates
Solution Approach 1:
The system performs self-checking by automatically detecting abnormal values through the control device. When an abnormal value is detected, the system automatically provides feedback and allows for remeasurement. This self-service approach to quality control maintains fast measurement processing while ensuring data reliability, as the system actively identifies and flags problematic measurements without requiring manual verification of each data point.
Data Source
AI summary
A technique for effectively detecting abnormal values in electromagnetic wave measurement is provided. An electromagnetic wave measuring device includes a measurement data receiving unit 308, an abnormal value detecting unit 309, and a GUI controlling unit 306. The measurement data receiving unit 308 receives measurement data of electromagnetic waves that are measured at multiple positions. The abnormal value detecting unit 309 detects an abnormal value in the measurement data. The GUI controlling unit 306 displays a position at which the abnormal value is measured, on a display.