Ethernet PSE Power Quota Management for Stable PD Supply
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
In existing power over Ethernet (POE) systems, multiple powered devices (PDs) requesting power simultaneously can cause unstable power consumption, leading to overload protection triggers and power hiccups due to fluctuating power demands during startup, resulting in inefficient power distribution and unstable power supply.
Innovation Solution
An Ethernet Power Sourcing Equipment (PSE) with a controller that calculates a remaining power quota based on allocated and measured power consumption, determining the power quota for each PD during startup and power supply stages to manage power distribution effectively, ensuring sufficient power for all devices and preventing power hiccups.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Productivity
If the Ethernet PSE supplies power to multiple PDs simultaneously during startup stage, then the power consumption of PDs increases rapidly, but the power stability deteriorates and overload protection is triggered
Solution Approach 1:
The controller performs preliminary assessment of remaining power quota before allowing PDs to enter the startup stage. By calculating the remaining power quota based on allocated power quotas of PDs in startup stage and measured power consumption of PDs in power supply stage, the system prepares in advance to prevent overload conditions, thus maintaining both fast power supply and stability
Solution Approach 2:
The controller continuously monitors measured power consumption of PDs in the power supply stage and uses this feedback to calculate the remaining power quota. This feedback mechanism allows the system to adjust power allocation dynamically, ensuring that multiple PDs can start up simultaneously without triggering overload protection, thereby maintaining power supply stability while enabling rapid power delivery
2Measurement precision
If the Ethernet PSE calculates remaining power quota based on measured power consumption of PDs in startup stage, then the measurement accuracy improves, but the power consumption fluctuation increases causing power hiccups
Solution Approach 1:
The system performs preliminary calculation of remaining power quota based on allocated power quotas before PDs fully enter the power supply stage. This preliminary action uses the allocated power quota (determined during grading stage) as a more stable basis for calculation, avoiding the fluctuations inherent in measuring actual power consumption during the unstable startup phase
Solution Approach 2:
The controller maintains a remaining power quota that acts as a cushion or buffer. By calculating this quota based on allocated power quotas rather than fluctuating measured consumption during startup, the system creates a safety margin that prevents power hiccups and ensures continuous stable power supply even as PDs transition through startup stages
3Object-affected harmful factors
If the Ethernet PSE triggers overload protection mechanism, then the power consumption of PDs is limited, but the power supply continuity is interrupted causing power hiccups
Solution Approach 1:
The controller calculates the remaining power quota in advance before overload conditions occur. By assessing the remaining power quota based on allocated power quotas of PDs in startup stage and measured consumption of PDs in power supply stage, the system prevents overload conditions from developing, thereby avoiding the need to trigger protection mechanisms that would interrupt power supply continuity
Solution Approach 2:
The continuous monitoring and recalculation of remaining power quota provides real-time feedback that allows the controller to adjust power allocation before overload conditions trigger protection mechanisms. This feedback loop ensures power supply continuity by preventing the need for protective shutdowns
Data Source
AI summary
An Ethernet power sourcing equipment (PSE) and a power management method thereof are provided. The Ethernet PSE includes a plurality of ports and a controller. Each port is coupled to a powered device (PD), to supply power to the PD through the port when the PD is in a power supply stage. When the PD enters a startup stage before the power supply stage, the controller calculates a remaining power quota based on a power quota allocated to the PD.