Continuous Glucose Sensor Self-Calibration via EIS Diagnostics

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Current continuous glucose monitoring systems require frequent finger stick calibrations due to limitations in sensor diagnostics and the need for reference glucose values, leading to inaccuracies and discomfort, with existing solutions failing to reliably minimize calibration needs and provide self-calibrating sensors.

Innovation Solution

The method involves using a glucose sensor with physical sensor electronics, a microcontroller, counter electrode, and working electrode to periodically measure electrode current signals, perform Electrochemical Impedance Spectroscopy (EIS) to generate EIS-related data, and determine valid blood glucose values, thereby calculating sensor glucose values and detecting calibration errors without external reference values.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Measurement precision

If external calibration using finger stick blood glucose meters is performed, then sensor accuracy is improved, but user discomfort and operational complexity increase

Engineering Contradiction:
Improvesensor accuracyVSAvoiduser discomfort
Core Design Contradiction:
Measurement precisionVSEase of operation

Solution Approach 1:

The sensor system performs self-calibration using internal reference measurements and self-diagnostics, eliminating the need for external finger stick calibrations. The microcontroller automatically adjusts calibration factors based on internal reference electrode measurements and detects sensor health status without requiring user intervention or causing discomfort.

Inventive Principle:
Principle #25Self-service

Solution Approach 2:

An internal reference electrode serves as an intermediary to provide stable reference potential measurements that enable automatic calibration. The reference electrode allows the system to self-correct drift and maintain accuracy without external calibration inputs, acting as a mediator between the sensing electrode and the measurement system.

Inventive Principle:
Principle #24Intermediary (Mediator)

2Measurement precision

If external calibration using finger stick blood glucose meters is performed, then sensor accuracy is improved, but calibration time and frequency requirements increase

Engineering Contradiction:
Improvesensor accuracyVSAvoidcalibration time
Core Design Contradiction:
Measurement precisionVSLoss of time

Solution Approach 1:

The sensor system continuously performs self-calibration and self-diagnostics throughout its operation. The microcontroller continuously monitors reference electrode measurements and automatically adjusts calibration factors in real-time, eliminating the need for periodic external calibration interruptions and reducing total calibration time.

Inventive Principle:
Principle #20Continuity of useful action

Solution Approach 2:

The system performs preliminary self-calibration during the initial warm-up period using internal reference measurements before external calibration would be needed. This preliminary action establishes baseline calibration factors that are continuously refined, reducing the frequency and time of required external calibrations.

Inventive Principle:
Principle #10Preliminary action

3Extent of automation

If sensor diagnostics are enhanced to reduce calibration needs, then system autonomy is improved, but device complexity increases

Engineering Contradiction:
Improvesystem autonomyVSAvoiddevice complexity
Core Design Contradiction:
Extent of automationVSDevice complexity

Solution Approach 1:

The microcontroller performs multiple functions including glucose measurement, self-calibration, self-diagnostics, and sensor health monitoring within a single integrated device. This multi-functionality enables high system autonomy without proportionally increasing device complexity, as the same processing unit handles all tasks.

Inventive Principle:
Principle #6Universality (Multi-functionality)

Solution Approach 2:

The reference electrode and sensing electrode systems are merged into a single sensor assembly with integrated electronics. The microcontroller combines processing of both electrode signals to simultaneously perform glucose measurement and self-calibration functions, reducing overall system complexity while maintaining autonomy.

Inventive Principle:
Principle #5Merging (Combining)

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

This approach reduces the need for frequent calibrations, enhances sensor reliability, and provides accurate glucose monitoring by utilizing EIS-based diagnostics to assess electrode health and sensor performance independently of glucose levels, leading to a more autonomous and reliable continuous glucose monitoring system.

Implementation Method 1

a sensor for producing signals indicative of a characteristic of a user

Methodology Applied
Scientific EffectElectrochemical reaction: Redox Reactions

Implementation Method 2

periodically performing, by the microcontroller, an Electrochemical Impedance Spectroscopy (EIS) procedure to generate EIS-related data for the working electrode

Methodology Applied
Scientific EffectElectrochemical Impedance Spectroscopy: Electrical Impedance Tomography

Data Source

PatentUS20240423514A1Methods, systems, and devices for continuous glucose monitoring
Publication Date: 2024.12.26 MEDTRONIC MINIMED INC
  • US20240423514A1 patent drawing
  • US20240423514A1 patent drawing
  • US20240423514A1 patent drawing

AI summary

A continuous glucose monitoring system may utilize electrode current (Isig) signals, Electrochemical Impedance Spectroscopy (EIS), and Vcntr values to optimize sensor glucose (SG) calculation in such a way as to enable reduction of the need for blood glucose (BG) calibration requests from users.