Problem

Conventional systems for controlling environmental parameters in buildings or homes, such as temperature and humidity, often fail to provide adequate and efficient control across multiple zones due to reliance on single thermostats and manual adjustments of dampers, leading to inefficiencies and discomfort.

Innovation Solution

An electronic controller system that monitors temperature and humidity levels across pre-defined zones, selects appropriate HVAC equipment stages based on zone demand, outside air temperature, and ductwork capacity, and adjusts air handler stages to optimize airflow and comfort.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Device complexity

If a single centrally located thermostat is used to control HVAC systems, then the system complexity is reduced and equipment cost is lowered, but the temperature control precision in various regions of the building deteriorates

Engineering Contradiction:
Improvesystem complexityVSAvoidtemperature control precision
Core Design Contradiction:
Device complexityVSMeasurement precision

Solution Approach 1:

The building is divided into multiple thermal zones, each with its own thermostat and control capabilities. This segmentation allows independent temperature control in different regions while using a centralized HVAC system, resolving the contradiction between system simplicity and regional temperature precision.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

Each zone is equipped with local thermostats that can independently control heating and cooling based on local temperature conditions. This local quality approach enables precise temperature control in each region without requiring complete system redesign.

Inventive Principle:
Principle #3Local quality

2Adaptability or versatility

If manually adjustable dampers and valves are installed in duct work throughout the building, then the adaptability to different regional needs is improved, but the ease of operation deteriorates due to time-consuming adjustments

Engineering Contradiction:
Improveadaptability to regional needsVSAvoidease of damper adjustment
Core Design Contradiction:
Adaptability or versatilityVSEase of operation

Solution Approach 1:

Manual dampers are replaced with motorized or electronically controlled dampers that can be dynamically adjusted based on thermostat signals and zone requirements. This dynamic control system automatically adapts to changing regional needs without requiring manual intervention, maintaining adaptability while dramatically improving ease of operation.

Inventive Principle:
Principle #15Dynamics

Solution Approach 2:

The system incorporates feedback loops where thermostats continuously monitor zone temperatures and automatically adjust damper positions to maintain desired temperature setpoints. This closed-loop control eliminates the need for manual adjustments while providing continuous adaptability to regional conditions.

Inventive Principle:
Principle #23Feedback

3Measurement precision

If multiple furnaces, air conditioners, and heat pumps are installed to service different rooms, then the temperature control precision in each zone is improved, but the device complexity and equipment cost increase

Engineering Contradiction:
Improvezone temperature control precisionVSAvoidequipment quantity
Core Design Contradiction:
Measurement precisionVSDevice complexity

Solution Approach 1:

The building is divided into multiple controllable zones with independent thermostats, but a single centralized HVAC plant is used to serve all zones. This segmentation approach achieves zone-level temperature control precision without requiring multiple complete HVAC systems, thereby avoiding the complexity and cost of multiple furnaces and air conditioners.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

A single multi-functional HVAC system is designed to serve multiple zones through a combination of variable speed air handlers, motorized dampers, and zone-specific thermostats. This universal system can provide heating, cooling, and airflow control to multiple zones simultaneously, achieving zone-level precision without the need for separate equipment in each zone.

Inventive Principle:
Principle #6Universality (Multi-functionality)

4Ease of operation

If the HVAC system is controlled by a single thermostat, then the ease of operation is improved, but the productivity of environmental control deteriorates due to inadequate temperature control in various regions

Engineering Contradiction:
Improveease of thermostat controlVSAvoidenvironmental control effectiveness
Core Design Contradiction:
Ease of operationVSProductivity

Solution Approach 1:

The control system is segmented into multiple independent thermostat zones, each capable of autonomous operation. This allows the system to maintain ease of operation with simple thermostat interfaces while dramatically improving environmental control effectiveness by addressing the specific temperature needs of each zone independently.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

Each zone is equipped with its own thermostat that can independently make control decisions based on local temperature conditions. This self-service capability allows zones to automatically adjust their environmental control without requiring centralized coordination, improving overall system effectiveness while maintaining operational simplicity.

Inventive Principle:
Principle #25Self-service

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The system provides precise control of environmental parameters, reducing energy consumption and enhancing comfort by ensuring that heating, cooling, and ventilation are concentrated only where needed, while allowing for flexible operating modes and incorporating humidification and dehumidification techniques.

Implementation Method 1

Heat pumps use a refrigeration system to cool air and use the same refrigeration system run in reverse to heat air.

Methodology Applied
Scientific EffectRefrigeration cycle:

Implementation Method 2

The electronic controller may include a temperature sensor to detect a loop temperature of a loop field of a geo-thermal heat pump.

Methodology Applied
Scientific EffectTemperature sensing:

Data Source

PatentUS8621881B2System and method for heat pump oriented zone control
Publication Date: 2014.01.07 ARZEL ZONING TECH
  • US8621881B2 patent drawing
  • US8621881B2 patent drawing
  • US8621881B2 patent drawing

AI summary

A system and method to control environmental parameters of pre-defined zones within an environment using an electronic controller. An electronic controller monitors a loop temperature of a loop field of a geo-thermal heat pump as detected by a temperature sensor connected to the loop field. The electronic controller selects a staging combination of the geo-thermal heat pump and an auxiliary HVAC equipment based on at least the loop temperature. The electronic controller activates the selected staging combination, to modify at least a portion of the environmental parameters, using non-proprietary activating signals provided by the electronic controller.