Controlling HVAC speed of condenser fans using pressure sensors

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

HVAC systems in earthmoving equipment face challenges in diagnosing issues like clogged fans and low refrigerant levels, leading to potential damage to expensive components and increased operating costs due to inefficient cooling and energy wastage.

Innovation Solution

A controller system that senses ambient temperature and compressor pressures to adjust condenser fan speed and direction, detects low suction pressure, and alerts for potential refrigerant issues, allowing for optimized operation and energy savings by continuously adjusting fan speed and reversing the fan to clear debris.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Loss of energy

If continuous control of condenser fan speed is implemented, then energy consumption is reduced and cooling efficiency is improved, but device complexity increases due to additional sensors and control systems

Engineering Contradiction:
Improveenergy consumptionVSAvoiddevice complexity
Core Design Contradiction:
Loss of energyVSDevice complexity

Solution Approach 1:

The system implements feedback control by continuously monitoring compressor discharge pressure and ambient temperature, then adjusting condenser fan speed accordingly. Pressure sensors provide real-time feedback on system conditions, and the controller uses this feedback to optimize fan operation, reducing energy consumption while maintaining effective cooling.

Inventive Principle:
Principle #23Feedback

Solution Approach 2:

The condenser fan operates dynamically with variable speed rather than at fixed speeds. The fan speed continuously adjusts based on real-time system conditions (pressure and temperature), allowing the system to optimize energy consumption across varying operating conditions while maintaining cooling effectiveness.

Inventive Principle:
Principle #15Dynamics

2Temperature

If fan speed is increased to improve cooling, then cooling efficiency improves, but energy consumption increases

Engineering Contradiction:
Improvecooling efficiencyVSAvoidenergy consumption
Core Design Contradiction:
TemperatureVSUse of energy by moving object

Solution Approach 1:

The system uses dynamic fan speed adjustment rather than fixed high-speed operation. Fan speed varies continuously based on actual cooling needs determined by pressure and temperature sensors, ensuring optimal cooling efficiency while minimizing energy consumption at each operating condition.

Inventive Principle:
Principle #15Dynamics

Solution Approach 2:

The system changes the operating parameters (fan speed, direction) based on measured system conditions. By adjusting fan speed as a variable parameter rather than maintaining constant high speed, the system achieves effective cooling while reducing unnecessary energy consumption during partial-load conditions.

Inventive Principle:
Principle #35Parameter changes

3Reliability

If the fan is reversed to clear debris, then reliability is improved by preventing clogged fans, but device complexity increases due to reversible fan mechanism

Engineering Contradiction:
ImprovereliabilityVSAvoiddevice complexity
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

The system performs preliminary maintenance action by periodically reversing the fan to prevent debris accumulation before it causes problems. This preventive reversal clears potential blockages before they can lead to fan failure or system shutdown, improving reliability without requiring complex additional components.

Inventive Principle:
Principle #10Preliminary action

Solution Approach 2:

The system uses fan reversal (operating in the opposite direction) to achieve a maintenance function. By temporarily running the fan in reverse, the system clears debris from condenser fins and fan blades, preventing clogged fans and improving system reliability without requiring separate cleaning mechanisms.

Inventive Principle:
Principle #13The other way round (Inversion)

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The system effectively prevents compressor damage, reduces energy consumption, and maintains efficient cooling by continuously adjusting fan speed and reversing the fan to clear debris, thereby improving equipment availability and lowering operational costs.

Implementation Method 1

a condenser fan that provides cooling to the condenser, the condenser fan having variable speed and reversible direction

Methodology Applied
Scientific EffectForced Convection: Forced Convection

Implementation Method 2

a compressor that is selectively operable responsive to a compressor control signal

Methodology Applied
Scientific EffectCompression: Compression

Implementation Method 3

an expansion valve fluidly coupled to the condenser

Methodology Applied
Scientific EffectPressure Drop: Pressure Drop

Implementation Method 4

an evaporator fluidly coupled to the expansion valve and the compressor

Methodology Applied
Scientific EffectEvaporation: Evaporation

Data Source

PatentUS9809088B2Controlling HVAC speed of condenser fans using pressure sensors
Publication Date: 2017.11.07 CATERPILLAR INC
  • US9809088B2 patent drawing
  • US9809088B2 patent drawing
  • US9809088B2 patent drawing

AI summary

A controller for a heat, ventilation, and air conditioning (HVAC) unit may comprise a compressor control signal output; a condenser fan control signal output; a pressure sensor input that receives information regarding an output pressure of the compressor; a temperature input that receives information regarding ambient temperature; a processor coupled to the compressor control signal output, the condenser fan control signal output, the first pressure sensor input, and the temperature input; and a computer-readable memory that stores instructions. The processor may cause the controller to: turn on the compressor via the compressor control signal output based on a request for air conditioning, select a condenser fan speed, from condenser fan control data stored in the computer readable memory, based on the ambient temperature and an output pressure of the compressor, and set a speed of the condenser fan to the selected condenser fan speed via the condenser fan control signal.