Problem
Existing adapter frames and shielding cages face issues with electromagnetic interference (EMI) leakage and thermal conductivity due to manufacturing misalignments and the use of sheet metal, which leads to gaps and stress on mounting pins, compromising signal transmission and heat dissipation in high-speed electronic systems.
Innovation Solution
A hybrid adapter frame design featuring a die-cast solid body with integrated heat sinks and elastic contact members, along with a sheet metal base plate, provides reliable thermal contact and EMI shielding by using a single heat sink that spans multiple module-receiving bays and includes resilient contact arms to maintain module alignment and contact, while robust mounting capabilities resist insertion stresses.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Ease of manufacture
If sheet metal is used to manufacture shielding cages, then ease of manufacture is improved, but manufacturing precision deteriorates causing gaps and misalignment
Solution Approach 1:
The patent combines die-cast aluminum (for precision EMI shielding) with sheet metal (for cost-effective mounting features) in a hybrid adapter frame construction. The die-cast portion provides precise tolerances for EMI-critical surfaces while sheet metal sections provide economical mounting capabilities, thus resolving the contradiction between manufacturing ease and precision.
Solution Approach 2:
The adapter frame is divided into multiple sections: die-cast EMI shielding portions and sheet metal mounting portions. This segmentation allows each part to be optimized for its specific function - die-casting for precision shielding and sheet metal for easy manufacture and mounting.
2Ease of manufacture
If compliant pins are used for mounting, then ease of manufacture is improved, but reliability deteriorates due to stress and excessive loads
Solution Approach 1:
The mounting structure uses a composite approach combining rigid die-cast mounting tabs with flexible resilient arms. The rigid tabs provide structural strength to resist insertion forces while the resilient arms provide compliance and stress absorption, improving reliability without sacrificing manufacturability.
Solution Approach 2:
The mounting structure incorporates dynamic elements - resilient arms that can flex and absorb stress during module insertion. This dynamic capability allows the mounting structure to accommodate manufacturing tolerances and insertion forces without failing, improving reliability.
3Temperature
If heat sink rim contact is used, then thermal conductivity is improved, but manufacturing precision deteriorates causing gaps and EMI leakage
Solution Approach 1:
The heat sink mounting uses resilient arms that can flex to accommodate manufacturing tolerances. This dynamic compliance ensures continuous thermal contact between the heat sink and module even when precise alignment is difficult to achieve, maintaining thermal conductivity without requiring extreme manufacturing precision.
Solution Approach 2:
The resilient mounting structure changes the physical state from rigid fixed contact to flexible compliant contact. This parameter change allows the system to accommodate dimensional variations while maintaining effective thermal contact, resolving the contradiction between thermal conductivity and manufacturing precision.
4Object-affected harmful factors
If openings are made smaller to reduce EMI leakage, then object-affected harmful factors are reduced, but device complexity increases
Solution Approach 1:
The adapter frame uses die-cast construction for the EMI-critical shielding portions, which allows for more complex integrated EMI shielding features without proportionally increasing overall device complexity. The die-casting process can incorporate integrated EMI shields and complex geometries in a single manufacturing step.
Applied Scientific Principles
This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.
Function Achieved in This Case
The solution effectively reduces EMI leakage and enhances thermal conductivity, ensuring reliable signal transmission and heat dissipation in high-speed systems by maintaining consistent contact between modules and heat sinks, even with manufacturing tolerances, and resisting insertion stresses through robust mounting.
Implementation Method 1
Pluggable modules used in high-speed systems generate significant heat, which must be carried away from the module in order to keep its operating temperature down to a level for which it was designed
Implementation Method 2
The resilient contact members are formed of spring material and extend beyond the plane of the base plate toward the heat sink. The contact members are positioned esp. centrally in the adapter frame above a receptacle connector.
Data Source
AI summary
A receptacle assembly with improved EMI leakage reduction and construction is described. The assembly includes a housing in the form of a guide frame that has a hollow interior which accommodates the insertion of an electronic module therein. A heat sink is provided to dissipate heat generated during operation of a module and the heat sink has a base portion that defines a ceiling of the hollow interior. An opening in the top of the guide frame provides an attachment location for the heat sink. A separately formed base plate is inserted into the housing and it defines a bottom of the interior of the housing.