Improved rack mounting kit for telecommunications equipment and rack cross brace
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
Traditional rack mount kits require multiple people to safely and reliably install heavy and large telecommunications equipment chassis into racks, which are prone to lateral flexibility, making single-person installation difficult due to space constraints and heat dissipation requirements.
Innovation Solution
A rack mounting kit with complimentary brackets providing a shelf-like edge for the chassis to rest upon and a removable cross brace to reduce lateral movement, allowing single-person installation by stabilizing the chassis during alignment and securing it with latch mechanisms.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Ease of operation
If traditional rack mount kits are used, then multiple people are required for installation, but this increases labor requirements and installation complexity
Solution Approach 1:
The patent introduces a cross brace as an intermediary component that temporarily supports the chassis during installation. This mediator allows a single person to install heavy equipment by providing additional support points, eliminating the need for multiple people while maintaining installation safety and reliability
Solution Approach 2:
The mounting system is divided into separate functional components: vertical rails for structural support, cross braces for lateral stability, and latch mechanisms for securing. This segmentation allows each component to perform its specific function independently, simplifying the overall installation process for a single operator
2Temperature
If racks are designed with open space for heat dissipation, then heat can be dissipated, but this reduces the number of device chassis that can be fitted in the rack
Solution Approach 1:
The rack design implements local quality by providing different spatial characteristics in different regions: open spaces are strategically positioned for heat dissipation pathways, while densely packed mounting positions maximize equipment capacity. The cross brace structure provides localized support that enables this differentiated spatial arrangement
3Productivity
If racks are designed for maximum equipment capacity, then space constraints are addressed, but lateral flexibility increases making installation difficult
Solution Approach 1:
The cross brace is designed as a dynamic support element that can be temporarily installed during the installation process to provide lateral stability, then removed after the chassis is secured. This dynamic approach allows the rack to transition from a flexible state (during installation) to a stable state (during operation), resolving the contradiction between installability and structural integrity
4Productivity
If device chassis are heavy and large in size, then equipment capacity is increased, but single-person installation becomes unsafe and unreliable
Solution Approach 1:
The cross brace acts as a mechanical intermediary that distributes and shares the load of heavy chassis during installation. By providing additional support points and creating a more stable temporary structure, it enables a single person to safely handle and position heavy equipment that would otherwise require multiple operators
Solution Approach 2:
The cross brace is pre-installed on the rack before the chassis is introduced. This preliminary action creates a prepared support structure that guides and stabilizes the chassis during the installation process, ensuring safety and reliability for heavy equipment handling by a single person
Data Source
Figure 1
Figure 2
Figure 3
AI summary
A rack mounting kit is configured to allow mounting of a telecommunications equipment chassis into a rack by a single person. The rack mounting kit includes two complimentary brackets that form a shelf-like feature. The complimentary brackets also include a mating latch for interfacing with a chassis to secure the chassis in place. Additionally, a cross brace is provided that is removably installed onto the two complimentary brackets to provide additionally rigidity to a rack while a chassis is being installed. The cross brace can be removed once installation of the chassis is complete.