Integrated Bus Plug for Flush IT Rack Power Distribution
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
Conventional IT rack power distribution using busways with receptacles and cords is cumbersome, costly, and difficult to install, as it requires multiple connections and takes up significant space.
Innovation Solution
Integration of plug-in stabs within the IT rack that directly connect to a busway without external cords or receptacles, allowing the rack to be flush-mounted and secured with clamps, with the option for mobile racks and accessible breaker/switches for power disconnection.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Ease of operation
If receptacles and cords are used to connect busway to equipment in IT racks, then power distribution is achieved, but space is consumed and installation becomes cumbersome
Solution Approach 1:
The bus plug is integrated directly into the IT rack structure, merging the power connection function with the rack itself. This eliminates the need for separate receptacles and cords, reducing space consumption while simplifying installation. The busway connects directly to the integrated bus plug through a streamlined interface.
2Ease of manufacture
If receptacles and cords are used for power connection, then power distribution is achieved, but installation difficulty increases and cost increases
Solution Approach 1:
Multiple power connection functions are merged into a single integrated bus plug structure. The bus plug incorporates all necessary electrical connections and mounting features directly into the rack, eliminating the need for multiple separate receptacles and cords, thereby reducing installation complexity.
Solution Approach 2:
The integrated bus plug serves multiple functions simultaneously: it provides electrical power distribution, structural mounting, and cable management. This multi-functional design reduces the overall number of components needed and simplifies the installation process.
3Volume of moving object
If bus plugs are integrated with IT rack, then space is reduced and installation is simplified, but power disconnection accessibility may be affected
Solution Approach 1:
The breaker or switch component is segmented from the main bus plug body and positioned in an accessible location on the rack. This allows the power disconnection mechanism to be easily accessed by technicians while the main bus plug remains integrated into the rack structure for space efficiency.
Solution Approach 2:
Instead of hiding the breaker/switch within the integrated bus plug structure, the design inverts the approach by positioning the breaker/switch externally on the rack surface. This makes the power disconnection mechanism more accessible while maintaining the compact integrated design of the bus plug itself.
Data Source
AI summary
Busways and Information technology enclosures and related systems are provided. A busway for power distribution to equipment positioned in an information technology (IT) rack is provided, the busway including a plurality of openings on a first surface of the busway configured to receive a plurality of plug-in stabs associated with a plurality of bus plugs integrated with the IT rack, such that when the plurality of plug-in stabs are positioned in the plurality of openings in the busway, the IT rack is substantially flush with the first surface of the busway.