IV Catheter Securement Dressing with Transparent Seal

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Current methods for securing and sealing IV catheters are inadequate, leading to high failure rates due to inadequate stabilization, contamination, and premature removal, which increases healthcare costs and patient discomfort.

Innovation Solution

A sterile dressing with a catheter securement plate and cover that provides a durable seal and securement, using a hydrocolloid adhesive and clear breathable film to stabilize the catheter, while allowing visualization of the insertion site and incorporating antimicrobial agents to maintain sterility.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Reliability

If traditional IV catheter securing methods are used, then the catheter can be inserted quickly, but the catheter has high failure rate due to inadequate stabilization and contamination

Engineering Contradiction:
Improvecatheter dwell timeVSAvoidsecuring device structure
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

The securing device is divided into multiple functional segments: a base layer with adhesive for skin attachment, a transparent film layer for sealing and visualization, and a catheter stabilization component. This segmentation allows each layer to perform its specific function optimally while working together to prevent catheter failure.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

The catheter is nested within the securing device structure, with the catheter hub positioned within a recessed area of the base layer, and the transparent film layered over both the catheter and base layer. This nested arrangement ensures the catheter is fully enclosed and protected while maintaining a compact overall structure.

Inventive Principle:
Principle #7Nested doll (Nesting)

2Object-affected harmful factors

If a sealed dressing is applied to protect the catheter insertion site, then contamination risk is reduced, but visualization of the insertion site becomes difficult

Engineering Contradiction:
Improvecontamination riskVSAvoidinsertion site visibility
Core Design Contradiction:
Object-affected harmful factorsVSLoss of information

Solution Approach 1:

A transparent flexible film is used as the sealing layer of the dressing. This thin film provides an effective barrier against contamination while maintaining optical transparency, allowing continuous visualization of the catheter insertion site and surrounding skin without compromising the sterile seal.

Inventive Principle:
Principle #30Flexible shells and thin films

3Stability of the object's composition

If the catheter is firmly secured to prevent dislodgement, then catheter stability is improved, but patient discomfort and risk of traumatic dislodgement increase

Engineering Contradiction:
Improvecatheter position stabilityVSAvoidtraumatic dislodgement risk
Core Design Contradiction:
Stability of the object's compositionVSObject-affected harmful factors

Solution Approach 1:

The adhesive base layer provides firm attachment at the skin-catheter interface to prevent dislodgement, while the transparent film provides a softer, more compliant sealing layer that reduces mechanical stress on the catheter. This gradient of attachment strength from the skin outward allows stable secures while minimizing trauma risk.

Inventive Principle:
Principle #3Local quality

4Productivity

If repeated catheter removal and re-insertion occurs due to failure, then immediate catheter function is restored, but healthcare costs and patient discomfort increase

Engineering Contradiction:
Improvecatheter insertion efficiencyVSAvoidtotal catheter care time
Core Design Contradiction:
ProductivityVSLoss of time

Solution Approach 1:

The catheter is secured with a comprehensive securing device during the initial insertion procedure, including proper positioning within the base layer and sealing with the transparent film. This preliminary action of thorough secures during insertion prevents subsequent failures that would require removal and re-insertion, reducing total catheter care time despite the slightly longer initial application process.

Inventive Principle:
Principle #10Preliminary action

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The dressing extends the safe dwell time of IV catheters, reduces the risk of contamination and traumatic dislodgement, and simplifies catheter care, thereby decreasing healthcare costs and improving patient outcomes.

Implementation Method 1

The catheter securement plate can have a plate adhesive disposed on at least a portion of its bottom surface to facilitate attachment to a patient's skin

Methodology Applied
Scientific EffectAdhesion: Adhesive

Implementation Method 2

clear breathable film to stabilize the catheter, while allowing visualization of the insertion site

Methodology Applied
Scientific EffectLight transmission: Light

Data Source

PatentUS12076507B2Integrated sealing and securing device for vascular catheters and methods for use of same
Publication Date: 2024.09.03 ONE IV SOLUTIONS LLC
  • US12076507B2 patent drawing
  • US12076507B2 patent drawing
  • US12076507B2 patent drawing

AI summary

A device for sealing and securing a catheter at its insertion site in order to provide for optimum safe catheter function, and to achieve maximum catheter longevity/dwell time is described. The sterile seal achieved by this device fully protects the catheter and its insertion site from external contamination. The unique sterile seal also functions to fully stabilize and secure the catheter, thereby minimizing traumatic catheter injury and loss. A means of continuously viewing the insertion site is also provided, as well as mechanisms for maintaining sterility of the sterile chamber that is formed around the catheter insertion site by the integrated sealing and securing device. Together these features allow for improved catheter safety and function, and allow catheters to safely remain in place for an extended period of time. The need to change catheter dressings at intervals is minimized or eliminated.