Laser Ultrasonic Motion Detection for Tomography Artifact Reduction

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Tomography imaging systems face challenges in reducing motion artifacts due to patient movement during scans, leading to unreliable diagnoses and increased workload for correcting image quality.

Innovation Solution

A medical device system incorporating a laser ultrasonic component to detect movement information within the patient, which is used to adjust scan parameters and image reconstruction parameters, thereby improving image quality by minimizing motion artifacts.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Manufacturing precision

If a patient remains still during a tomography scan, then image quality is improved, but the scan time increases and patient comfort deteriorates

Engineering Contradiction:
Improveimage qualityVSAvoidscan time
Core Design Contradiction:
Manufacturing precisionVSLoss of time

Solution Approach 1:

The system performs preliminary detection of patient movement using laser ultrasonic components before and during the scan to establish baseline movement patterns. This allows the reconstruction algorithm to pre-compensate for expected motion artifacts, reducing the need for repeated scans and minimizing total scan time while maintaining image quality.

Inventive Principle:
Principle #10Preliminary action

Solution Approach 2:

The system continuously monitors patient movement during scanning using laser ultrasonic sensors and provides real-time feedback to adjust scan parameters and reconstruction algorithms. This closed-loop feedback mechanism enables dynamic compensation for motion artifacts without requiring the patient to remain completely still, thereby reducing scan time while preserving image quality.

Inventive Principle:
Principle #23Feedback

2Loss of time

If a patient moves during a tomography scan, then scan time is reduced, but motion artifacts increase and diagnostic reliability deteriorates

Engineering Contradiction:
Improvescan timeVSAvoiddiagnostic reliability
Core Design Contradiction:
Loss of timeVSReliability

Solution Approach 1:

The system replaces traditional mechanical contact-based motion detection with laser ultrasonic non-contact detection. This substitution allows for continuous, high-precision monitoring of patient movement without physical interference, enabling accurate detection and compensation of motion artifacts even when patients move, thus maintaining diagnostic reliability without extending scan time.

Inventive Principle:
Principle #28Mechanics substitution (Replace mechanical system)

Solution Approach 2:

The system dynamically adjusts scan parameters and reconstruction algorithms based on detected movement patterns. By changing parameters such as acquisition timing, reconstruction weighting, and artifact suppression thresholds in response to measured motion, the system maintains diagnostic reliability even when patients move during scanning.

Inventive Principle:
Principle #35Parameter changes

3Manufacturing precision

If laser ultrasonic components are added to detect movement, then motion artifacts are reduced, but device complexity increases

Engineering Contradiction:
Improveimage qualityVSAvoiddevice complexity
Core Design Contradiction:
Manufacturing precisionVSDevice complexity

Solution Approach 1:

The laser ultrasonic components serve multiple functions: they detect patient movement, characterize tissue properties, and provide guidance for reconstruction algorithms. This multi-functionality reduces the need for separate detection systems, thereby limiting the increase in device complexity while achieving motion artifact reduction and improved image quality.

Inventive Principle:
Principle #6Universality (Multi-functionality)

Solution Approach 2:

The system merges the laser ultrasonic detection components with the existing tomography imaging system, integrating motion detection and image acquisition into a unified platform. This integration shares common infrastructure such as data processing units, control systems, and patient positioning mechanisms, thereby reducing the overall complexity increase that would result from adding separate detection equipment.

Inventive Principle:
Principle #5Merging (Combining)

4Manufacturing precision

If movement detection is performed during scanning, then motion artifacts are reduced, but processing time increases

Engineering Contradiction:
Improveimage qualityVSAvoidprocessing time
Core Design Contradiction:
Manufacturing precisionVSLoss of time

Solution Approach 1:

The system performs preliminary characterization of patient movement patterns using laser ultrasonic detection before the main scan. By establishing baseline motion patterns in advance, the reconstruction algorithm can pre-plan compensation strategies, reducing the computational burden during actual image reconstruction and minimizing processing time while maintaining image quality.

Inventive Principle:
Principle #10Preliminary action

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The system effectively reduces motion artifacts in tomographic images, enhancing diagnostic accuracy and reducing the workload associated with image correction.

Implementation Method 1

The ultrasonic signal may be acquired by at least one laser ultrasonic component of a medical device

Methodology Applied
Scientific EffectLaser ultrasonic: Photoacoustic Effect

Data Source

PatentUS12011249B2Systems and methods for tomography imaging
Publication Date: 2024.06.18 SHANGHAI UNITED IMAGING HEALTHCARE
  • US12011249B2 patent drawing
  • US12011249B2 patent drawing
  • US12011249B2 patent drawing

AI summary

The present disclosure provides systems and methods for tomography imaging. The systems and methods may obtain an ultrasonic signal indicating a movement state of a position of an object (e.g., a position inside the object). The ultrasonic signal may be acquired by at least one laser ultrasonic component of a medical device. The systems and methods may determine, based on the ultrasonic signal, movement information of the position of the object. The systems and methods may obtain, based on the movement information of the position, target image data of the object using an imaging component of the medical device.