Liquid-Cooled Rack Heat Exchanger for EMI Shielding

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Rack-mount server systems face challenges in efficiently cooling high-density electronic components while managing increasing electromagnetic interference (EMI) emissions, which necessitates effective space utilization and cost reduction.

Innovation Solution

A cooling system incorporating a heat exchanger with a liquid circulation path and an airflow path structure that transfers heat and shields EMI, utilizing materials with high heat conductivity and electromagnetic absorption properties, such as metals and ceramics, to facilitate efficient cooling and EMI shielding in a compact design.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Area of stationary object

If separate cooling and EMI shielding structures are used, then cooling and shielding functions are achieved, but space and cost increase

Engineering Contradiction:
Improvespace utilizationVSAvoidnumber of components
Core Design Contradiction:
Area of stationary objectVSDevice complexity

Solution Approach 1:

The patent combines the cooling function and EMI shielding function into a single integrated heat exchanger structure. The heat exchanger includes both cooling channels for liquid circulation and EMI shielding layers, eliminating the need for separate cooling systems and EMI shielding structures, thereby reducing space utilization and component count.

Inventive Principle:
Principle #5Merging (Combining)

Solution Approach 2:

The heat exchanger is designed as a multi-functional component that simultaneously performs cooling and EMI shielding. The structure includes cooling channels for thermal management and integrated EMI shielding layers made of conductive materials, allowing one component to fulfill multiple protective and functional roles.

Inventive Principle:
Principle #6Universality (Multi-functionality)

2Productivity

If high-density electronic components are deployed, then productivity increases, but heat density and EMI emissions increase

Engineering Contradiction:
Improveelectronic component densityVSAvoidheat density
Core Design Contradiction:
ProductivityVSTemperature

Solution Approach 1:

The heat exchanger is positioned in close proximity to high-density electronic components to provide localized cooling where heat generation is most intense. The liquid cooling channels are strategically arranged to target specific hot spots, and EMI shielding layers are placed near components generating significant electromagnetic interference, providing customized thermal and electromagnetic management for different zones.

Inventive Principle:
Principle #3Local quality

3Temperature

If traditional cooling systems are used, then cooling function is achieved, but space and cost increase

Engineering Contradiction:
Improvecooling efficiencyVSAvoidsystem volume
Core Design Contradiction:
TemperatureVSVolume of stationary object

Solution Approach 1:

The EMI shielding layers are integrated within the walls and structure of the heat exchanger itself, nesting the shielding function inside the cooling component. This nested design allows the EMI shielding material to be part of the heat exchanger structure rather than an external addition, significantly reducing the overall system volume while maintaining both cooling and shielding functions.

Inventive Principle:
Principle #7Nested doll (Nesting)

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The solution achieves efficient cooling and EMI shielding in a single component, reducing space and cost within the rack-mounted server system, while allowing for flexible configuration based on heat densities and component placement.

Implementation Method 1

an airflow path structure in thermal contact with the liquid circulation path structure such that heat from air passing through the airflow path structure transfers to the coolant

Methodology Applied
Scientific EffectHeat transfer: Conduction (thermal)

Implementation Method 2

the airflow path structure is configured to shield electromagnetic interference

Methodology Applied
Scientific EffectElectromagnetic shielding: Faraday Cage

Data Source

PatentUS7804687B2Liquid-cooled rack with pre-cooler and post-cooler heat exchangers used for EMI shielding
Publication Date: 2010.09.28 ORACLE AMERICAN INC
  • US7804687B2 patent drawing
  • US7804687B2 patent drawing
  • US7804687B2 patent drawing

AI summary

A cooling system for a rack-mount server includes a fan disposed within the rack-mount server and configured to produce an airflow through the rack-mount server, and a heat exchanger disposed within the rack-mount server in a path of the airflow through the rack-mount server. The heat exchanger includes a liquid circulation path structure and an airflow path structure. The airflow path structure is configured to shield electromagnetic interference.