Magnetic Syringe Holder With Disposable Foam Cap Block
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
Existing syringe holders, such as those made of flexible foam, are unstable on surgical drapes, leave adhesive residue, and expose instruments to accidental strikes, necessitating improved stability and safety during medical procedures.
Innovation Solution
A rigid base block with elongated prongs and a pierceable receiving block, magnetically attached to a surface, securely holds syringes, allowing easy access and retraction of the needle with a single hand, and can be reused or discarded after a single use.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Ease of manufacture
If flexible foam holders with double-sided tape are used to hold syringes, then low cost and ease of manufacture are improved, but stability on surgical drapes deteriorates
Solution Approach 1:
The holder is divided into two functional blocks: a base block for mounting and a receiving block for holding the syringe. This segmentation allows each block to be optimized independently - the base block for stable mounting and the receiving block for secure syringe retention - thereby resolving the contradiction between ease of manufacture and stability.
Solution Approach 2:
The holder uses composite construction with a rigid base block (sterilizable, stable material) and a soft resilient receiving block (foam or elastomer). This composite approach combines the stability and durability of rigid materials with the grasping capability of soft materials, achieving both stability and ease of manufacture.
2Ease of manufacture
If adhesive tape is used to mount the holder on surfaces, then ease of manufacture is improved, but cleanliness and residue-free operation deteriorate
Solution Approach 1:
The adhesive mounting system is replaced with a mechanical mounting system using magnets. The base block contains magnets that attract to ferromagnetic surfaces or magnetic mounting blocks, providing secure mounting without adhesive residue. This substitution maintains ease of manufacture while eliminating the harmful adhesive residue effect.
3Ease of operation
If instruments protrude vertically from holders, then ease of access is improved, but safety from accidental strikes deteriorates
Solution Approach 1:
The syringe holding orientation is changed from vertical protrusion to horizontal positioning within the receiving block. The syringe lies horizontally with the needle tip oriented laterally, removing it from the vertical path where accidental strikes occur. This dimensional change maintains ease of access while eliminating the safety hazard of vertical protrusion.
4Productivity
If the holder is designed for reuse, then productivity is improved, but sterilization complexity increases
Solution Approach 1:
The holder is segmented into a reusable base block and a disposable receiving block. The base block is designed for sterilization and reuse, while the receiving block can be discarded after single use. This segmentation allows the system to achieve high productivity through reuse of the base block while simplifying sterilization requirements by making the receiving block disposable.
Applied Scientific Principles
This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.
Function Achieved in This Case
Provides stable, residue-free, and safe storage for syringes, reducing the risk of accidental dislodgement and injury, while maintaining sterility and ease of use.
Implementation Method 1
The mounting block 30 allows mounting of the base block 10 to the placement surface 200 in the manner shown in FIGS. 3a-3b, wherein the mounting block 30 is situated on the opposite side of the placement surface 200 from the base block 10 such that the base and mounting blocks 10 and 30 are magnetically bound to each other about the placement surface 200.
Data Source
AI summary
A medical instrument holder includes a base block configured to removably mount to a placement surface, and has prongs extending therefrom. A receiving block formed of soft and resiliently flexible material, such as an elastomeric foam, may be impaled on the prongs. A medical instrument (such as a syringe or scalpel) may be inserted into the receiving block, thereby effectively removably holding the medical instrument with respect to the placement surface. The receiving block may be discarded after use, and replaced with another receiving block for subsequent use. The holder is particularly useful for receiving the cap of a hypodermic syringe within the receiving block, allowing the syringe to be held in a ready-to-use location, and allowing one-handed removal of the syringe from the cap grasped by the receiving block.