Problem
Existing automotive cooling systems for power switches often rely on heat sinks with fluid-based active cooling, which can lead to coolant leaks and increased production and maintenance costs, while passive cooling structures lack design flexibility.
Innovation Solution
A combination of passive and active cooling systems, where a passive heat dissipation element thermally conducts heat to an active heat dissipation element, eliminating the need for a second active heat sink and reducing leak risks, with the passive element being enclosure-free and providing structural support.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Temperature
If fluid-based active cooling systems are used for power switches, then cooling efficiency is improved, but the risk of coolant leaks and maintenance costs increase
Solution Approach 1:
The cooling system is divided into two separate elements: a passive heat dissipation element that contacts one surface of the power switch and an active heat dissipation element that contacts the opposite surface. This segmentation allows the active cooling component to be minimized to a single element, reducing leak risks while maintaining cooling efficiency through the passive element's extended heat dissipation surface.
2Temperature
If multiple active heat sinks are used on both sides of power switches, then cooling performance is improved, but production costs and system complexity increase
Solution Approach 1:
The passive heat dissipation element and active heat dissipation element are thermally coupled through the power switch, creating a unified cooling system. The passive element extends the heat dissipation surface area while the single active element provides the necessary cooling, merging the functions of what would traditionally require multiple active heat sinks into a simpler two-element system.
3Reliability
If passive cooling structures are used, then leak risks are reduced, but design flexibility and cooling efficiency are limited
Solution Approach 1:
The passive heat dissipation element serves multiple functions: it extends the heat dissipation surface area, provides structural support, and thermally couples the power switch to the active heat dissipation element. This multi-functionality allows the passive element to contribute actively to cooling efficiency while maintaining its inherent reliability advantage of having no coolant containment.
4Temperature
If traditional heat sinks with fluid-based cooling are used, then cooling effectiveness is improved, but production and maintenance costs increase
Solution Approach 1:
The passive heat dissipation element is designed as a simple, low-cost component that can be easily manufactured and replaced if necessary. By using a passive element instead of a second active heat sink with coolant channels, the system reduces production costs while maintaining cooling effectiveness through the thermal coupling of the two elements.
Applied Scientific Principles
This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.
Function Achieved in This Case
This approach enhances cooling efficiency, reduces production and maintenance costs, and minimizes coolant leaks by utilizing a single active heat sink, while offering design flexibility and improved thermal conductivity.
Implementation Method 1
a passive heat dissipation element in contact with and facing a first surface of the one or more power switches... in thermal contact with the passive heat dissipation element
Implementation Method 2
Heat sinks provide effective means of dissipating heat by thermally conducting heat into a fluid medium
Data Source
AI summary
A power module, includes: one or more power switches; a passive heat dissipation element in contact with and facing a first surface of the one or more power switches, the passive heat dissipation element having a first planar surface and a second planar surface; and an active heat dissipation element in contact with and facing a second surface of the one or more power switches, wherein the active heat dissipation element is positioned opposite the passive heat dissipation element relative to the one or more power switches and is in thermal contact with the passive heat dissipation element.