Pressure-Regulated Cooling Loops for Data Center Heat Load Swings

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Current data center cooling systems face challenges in efficiently managing heat load variations, system failures, and maintaining reliability, particularly in high-performance IT environments, where temperature control and fluid management are critical for server performance and longevity.

Innovation Solution

A pressure-based cooling system design incorporating a buffer loop with a heat exchanger and pressure controllable valves, allowing for self-regulation of fluid pressure and flowrate, enabling flexible configurations and robust operation across different cooling loop arrangements.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Reliability

If traditional cooling systems are used to manage heat load variations, then the system structure is simple, but the reliability decreases when facing heat load variations and system failures

Engineering Contradiction:
Improvesystem reliabilityVSAvoidsystem complexity
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

The buffer unit is pre-filled with cooling fluid and integrated into the cooling loop before system operation. This preliminary preparation allows the buffer to immediately absorb pressure fluctuations and heat load variations when they occur, enhancing system reliability without requiring complex real-time control mechanisms.

Inventive Principle:
Principle #10Preliminary action

Solution Approach 2:

The buffer unit acts as an intermediary component between the heat source (IT equipment) and the cooling system. It mediates pressure and temperature fluctuations, isolating the impact of heat load variations from the rest of the cooling system, thereby improving reliability while maintaining relatively simple system architecture.

Inventive Principle:
Principle #24Intermediary (Mediator)

2Adaptability or versatility

If conventional fluid management is used, then the system is easy to operate, but the ability to dynamically adjust to heat load changes is insufficient

Engineering Contradiction:
Improveadaptability to heat load changesVSAvoidoperation complexity
Core Design Contradiction:
Adaptability or versatilityVSEase of operation

Solution Approach 1:

The buffer unit is designed to automatically respond to pressure and temperature changes without requiring external control or manual intervention. When heat load changes cause pressure fluctuations, the buffer unit self-regulates by absorbing or releasing cooling fluid, providing adaptability while maintaining ease of operation.

Inventive Principle:
Principle #25Self-service

Solution Approach 2:

The buffer unit provides dynamic adaptability by allowing the cooling fluid volume and pressure to vary in response to heat load changes. The system transitions from static fluid management to dynamic adjustment, enabling the cooling system to adapt to varying thermal conditions while keeping the operation simple through passive physical responses.

Inventive Principle:
Principle #15Dynamics

3Reliability

If standard cooling loops are used, then the device complexity is low, but the resilience to system failures and anomalies is reduced

Engineering Contradiction:
Improveresilience to failuresVSAvoidloop configuration complexity
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

The buffer unit serves as a cushioning element that is预先 prepared to absorb the impact of system failures and anomalies. By having excess cooling fluid stored in the buffer unit beforehand, the system can withstand pump failures, valve malfunctions, or sudden heat load spikes without immediate catastrophic failure, enhancing resilience while adding only one component to the loop.

Inventive Principle:
Principle #11Beforehand cushioning (Prior cushioning)

4Object-affected harmful factors

If pressure fluctuations are not regulated, then the system is simpler, but the impact on cooling fluid and server performance increases

Engineering Contradiction:
Improveimpact of pressure fluctuationsVSAvoidpressure regulation complexity
Core Design Contradiction:
Object-affected harmful factorsVSDevice complexity

Solution Approach 1:

The buffer unit acts as a mediator that absorbs and dampens pressure fluctuations before they can significantly impact the cooling fluid or server performance. By positioning the buffer unit in the cooling loop, it intercepts pressure variations and converts them into minimal fluid volume changes, reducing harmful effects while maintaining relatively simple pressure regulation.

Inventive Principle:
Principle #24Intermediary (Mediator)

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

This solution enhances thermal management and fluid distribution, ensuring high resilience and reliability by dynamically adjusting to heat load changes and system anomalies, reducing the impact of temperature and pressure fluctuations on cooling fluid, thereby extending server lifespan and maintaining performance.

Implementation Method 1

a heat exchanger coupled to the inlet port and the outlet port

Methodology Applied
Scientific EffectHeat exchange: Heat Exchanger

Implementation Method 2

a first pressure controllable valve coupled to the main loop and the buffer loop to selectively distribute at least a portion of the cooling fluid to at least one of the main loop or the buffer loop based on a fluid pressure of the cooling fluid

Methodology Applied
Scientific EffectPressure differential control: Pressure Gradient

Data Source

PatentUS11729953B2Pressure based regulating design in fluid conditioning and distribution system
Publication Date: 2023.08.15 BAIDU USA LLC
  • US11729953B2 patent drawing
  • US11729953B2 patent drawing
  • US11729953B2 patent drawing

AI summary

A cooling system includes an inlet port and an outlet port to be coupled to one or more electronic devices, a main loop having a heat exchanger coupled to the inlet port and the outlet port, and a buffer loop coupled to the inlet port and the outlet port. The main loop having a heat exchanger to receive fluid from the inlet port, to extract heat generated by the electronic devices and carried by the fluid, and to return the fluid to the electronic devices via the outlet. In an embodiment, a cooling system includes a buffer loop, configured in parallel with the main loop, with a buffer unit to temporarily buffer at least a portion of the fluid, and a first pressure controllable valve, coupled to the main loop and the buffer loop, to selectively distribute at least a portion of the fluid to at least one of the main loop or the buffer loop based on a fluid pressure of the fluid. In an embodiment, a cooling system includes a bypass loop coupled between the first pressure controllable valve and the outlet port to operate as a direct bypass loop from the inlet port to the outlet port, bypassing the heat exchanger and the buffer unit. Pressure is measured and used for controlling those loops under different working scenarios.