PSU Information Buffering to Prevent PMBUS Access Conflicts
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
In servers with multiple computing device assemblies, simultaneous access to a common power supply unit (PSU) through a power management bus (PMBUS) leads to resource competition, preventing some assemblies from accessing the PSU and affecting normal computing strategies.
Innovation Solution
Implementing a controller to pre-read and store PSU working information at predefined intervals, allowing timely transmission to computing device assemblies upon request, thereby avoiding resource competition and ensuring all assemblies can access the PSU.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Productivity
If multiple computing device assemblies access the PSU simultaneously through PMBUS, then the computing capability of unit volume is increased, but resource competition occurs causing some assemblies to be unable to access the PSU
Solution Approach 1:
The controller pre-reads the working information of the PSU at a predefined time interval and stores it locally. This preliminary action allows the controller to respond to search requests from multiple computing device assemblies without requiring them to simultaneously access the PSU, thereby eliminating resource competition while maintaining high computing capability.
2Productivity
If multiple computing device assemblies access the PSU at the same time, then resource utilization is improved, but access conflicts occur affecting normal computing strategies
Solution Approach 1:
The controller acts as an intermediary between the PSU and multiple computing device assemblies. It reads PSU information in advance and stores it locally, then provides this information to requesting assemblies without requiring direct simultaneous access to the PSU. This intermediary approach maintains high resource utilization while ensuring smooth, conflict-free access for all assemblies.
Data Source
AI summary
A method of reading information of a power supply unit (PSU) includes reading working information of the PSU at a predefined time interval. The working information is stored in a predefined storing space. When receiving a searching request sent to PSU from the computing device assembly, the working information is acquired from the predefined storing space and transmitted to the corresponding computing device assembly. The working information of the PSU is pre-read and stored, when several computing device assemblies read the working information of the PSU by the searching request at the same time, there is no issue of competition for resource, and the problem of the computing device assemblies being unable to access the PSU is avoided. Thus, a computing strategy of computing systems corresponding to the computing device assemblies is normally executed. A server and a computer readable storage medium are also disclosed.