Rear-Accessible Side-Bay Rack Layout for 48U Standard Capacity
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
Existing rack-mounted electronic systems face design challenges due to dimensional constraints imposed by industry standards, limiting access and flexibility in accommodating a large number of devices while maintaining compatibility and uniformity.
Innovation Solution
A rack configuration that supports up to 48U of devices within a 600mm wide and 1200mm deep frame, featuring vertically-spaced mounting holes, rear-accessible 1U side bays, and improved cable routing, allowing for full serviceability from both front and rear without removing the rack, while adhering to standard dimensions.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Adaptability or versatility
If standard rack dimensions are used, then compatibility with industry standards is improved, but device capacity and serviceability are worsened
Solution Approach 1:
The rack is divided into a central rack space and multiple side bays, with the side bays further segmented into front-accessible and rear-accessible sections. This segmentation allows the rack to accommodate more devices (48U total capacity) while maintaining standard dimensions, as each segment can be independently optimized for specific device types and access requirements.
Solution Approach 2:
The patent utilizes the depth dimension of the rack by incorporating side bays that extend outward from the central rack space. This dimensional expansion allows additional devices to be mounted without increasing the rack's width or height, thereby increasing device capacity while maintaining compliance with standard rack dimensions.
2Adaptability or versatility
If standard rack dimensions are used, then compatibility with industry standards is improved, but serviceability is worsened
Solution Approach 1:
The rack is divided into a central rack space and multiple side bays, with the side bays further segmented into front-accessible and rear-accessible sections. This segmentation allows the rack to accommodate more devices (48U total capacity) while maintaining standard dimensions, as each segment can be independently optimized for specific device types and access requirements.
Solution Approach 2:
Traditional racks require side access for servicing outer devices. This patent inverts the access pattern by providing rear access to side bays, allowing technicians to service devices from the rear without needing to approach the rack from the sides. This is achieved through rear-opening panels and rear-mounted cable management.
3Quantity of substance
If side access is required for outer devices, then device capacity is improved, but serviceability is worsened
Solution Approach 1:
Traditional racks require side access for servicing outer devices. This patent inverts the access pattern by providing rear access to side bays, allowing technicians to service devices from the rear without needing to approach the rack from the sides. This is achieved through rear-opening panels and rear-mounted cable management.
4Quantity of substance
If cable management is inefficient, then device capacity is improved, but ease of operation is worsened
Solution Approach 1:
The patent introduces cable management channels and apertures as intermediary structures that facilitate organized cable routing between devices in the central rack space and side bays. These channels provide dedicated pathways for cables, reducing clutter and improving ease of operation while maintaining high device capacity.
Data Source
AI summary
An embodiment of a computer rack is capable of supporting up to 48U of electronic devices, including a central rack space for up to 42U and six 1U side bays. The side bays are fully accessible from the rear of the rack, so that all of the components may be serviced without pulling the rack out from a row and removing side panels. Optional strip PDUs may be mounted at the rear. The rack complies with standard dimensions for a 19-inch rack, including standard vertical and horizontal rail dimensions, and fits on a standard 600 mm×1200 mm floor tile.