Redundant Generator Controllers for Reliability

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Generator systems face reliability issues due to single points of failure, such as controller failures and communication path disruptions, which can lead to entire system shutdowns and inability to supply power when needed.

Innovation Solution

Implementing redundant generator controllers and communication paths that allow independent operation and communication between generators, enabling one controller to take over if another fails and ensuring multiple paths for communication to prevent system-wide failures.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Reliability

If a single generator controller is used to control the generator system, then the device complexity is reduced, but the reliability deteriorates because a single point of failure can shut down the entire system

Engineering Contradiction:
Improvesystem reliabilityVSAvoidcontroller configuration
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

The generator system is divided into multiple independent control units, each capable of controlling the generator set independently. This segmentation eliminates single points of failure, as each controller can operate autonomously if another fails, directly resolving the reliability issue while maintaining manageable complexity through modular design

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

The system changes the control architecture parameter from a single centralized controller to multiple distributed controllers. This parameter change transforms the system from having one point of failure to having redundant failure points, thereby improving reliability while the modular nature keeps the complexity increase acceptable

Inventive Principle:
Principle #35Parameter changes

2Reliability

If a single communication path is used between controllers and generator sets, then the device complexity is reduced, but the reliability deteriorates because communication disruptions can cause system-wide failures

Engineering Contradiction:
Improvecommunication reliabilityVSAvoidcommunication path configuration
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

The communication architecture is segmented into multiple independent paths between controllers and generator sets. Each communication path operates independently, so if one path experiences disruption, other paths remain functional, ensuring continuous communication and preventing system-wide failures while maintaining reasonable complexity through standardized communication protocols

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

The system introduces redundant communication paths as intermediary channels between controllers and generator sets. These alternative communication routes act as mediators that can carry control signals and status information when primary paths fail, thereby improving communication reliability without significantly increasing overall system complexity

Inventive Principle:
Principle #24Intermediary (Mediator)

3Reliability

If the entire generator system is shut down when one device fails, then the ease of operation is maintained through simple failure response, but the reliability deteriorates because the system cannot continue providing power

Engineering Contradiction:
Improvepower supply continuityVSAvoidfailure response complexity
Core Design Contradiction:
ReliabilityVSEase of operation

Solution Approach 1:

The controller system implements self-service through automatic failover capabilities. When one controller fails, the remaining controller(s) automatically detect the failure and take over control functions without requiring manual intervention. This self-service mechanism ensures continuous power supply while keeping the operational response simple and automatic

Inventive Principle:
Principle #25Self-service

Solution Approach 2:

The system performs preliminary actions by pre-configuring redundant controllers and establishing failover protocols before failures occur. This preliminary preparation enables automatic takeover and continuous operation when failures happen, maintaining power supply continuity while simplifying the actual failure response through pre-established procedures

Inventive Principle:
Principle #10Preliminary action

Data Source

PatentUS10447076B2Redundant generator control
Publication Date: 2019.10.15 DISCOVERY ENERGY LLC
  • US10447076B2 patent drawing
  • US10447076B2 patent drawing
  • US10447076B2 patent drawing

AI summary

A generator system may include redundant control. The generator system may include any combination of redundant controllers, redundant communication paths, or other redundant control. A generator system may include an electrical bus, a first generator controller, and the second generator controller. The first generator controller may control a first generator breaker for connecting a first generator to the electrical bus and configured to control an external breaker for selectively connecting the electrical bus to an external source. The second generator controller may control a second generator breaker for connecting a second generator to the common bus and configured to control the external breaker for selectively connecting the electrical bus to the external source.