Remote Racking Unit for Circuit Breaker Arc Flash Safety

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Existing methods for remotely racking circuit breakers do not adequately address the risk of arc flash hazards during maintenance operations, as they lack a simple and effective apparatus for safely performing racking operations from a safe distance, putting maintenance personnel at risk of injury or death.

Innovation Solution

A remote racking unit with a stationary vertical support, wheels for mobility, an actuator for vertical movement, a motor mount structure for enhanced mechanical advantage, and electronic controls for safe and controlled operation, allowing for remote operation of circuit breakers without direct proximity.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Ease of operation

If maintenance personnel perform racking operations close to the circuit breaker, then operational control and precision are improved, but the risk of arc flash injury or death increases

Engineering Contradiction:
Improveoperational controlVSAvoidarc flash hazard
Core Design Contradiction:
Ease of operationVSObject-affected harmful factors

Solution Approach 1:

The patent introduces an extended reach tool as an intermediary device between the operator and the circuit breaker. This tool allows the operator to perform racking operations from a safe distance while maintaining full operational control through its mechanical design featuring multiple engagement positions and a locking mechanism that secures the breaker at each racking stage.

Inventive Principle:
Principle #24Intermediary (Mediator)

2Object-affected harmful factors

If a remote racking apparatus is used to increase safety distance, then arc flash protection is improved, but device complexity increases

Engineering Contradiction:
Improvearc flash protectionVSAvoidapparatus complexity
Core Design Contradiction:
Object-affected harmful factorsVSDevice complexity

Solution Approach 1:

The extended reach tool is segmented into multiple functional sections: an extended shaft for reach, multiple engagement positions for staged racking, and a locking mechanism for secure positioning. This segmentation allows the device to provide comprehensive safety features while maintaining relative simplicity through modular functional design.

Inventive Principle:
Principle #1Segmentation

3Object-affected harmful factors

If existing remote racking methods are used, then some arc flash protection is achieved, but reliability and safety are insufficient

Engineering Contradiction:
Improvearc flash protectionVSAvoidsafety reliability
Core Design Contradiction:
Object-affected harmful factorsVSReliability

Solution Approach 1:

The locking mechanism in the extended reach tool performs preliminary action by automatically securing the circuit breaker at each engagement position before the operator proceeds to the next racking stage. This ensures that the breaker is positively locked in place, preventing accidental disengagement or unintended contact with energized components, thereby enhancing safety reliability.

Inventive Principle:
Principle #10Preliminary action

Data Source

PatentUS8604369B2Circuit breaker remote racking device
Publication Date: 2013.12.10 INOLECT LLC
  • US8604369B2 patent drawing
  • US8604369B2 patent drawing
  • US8604369B2 patent drawing

AI summary

A device is provided for remotely racking circuit breakers and contactors that are housed within a housing structure, such as a circuit breaker cell or switchgear cabinet.