RF Amplifier Surge Protection Using Relay-Isolated Gas Discharge Tube

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Surge suppression circuitry in RF signal amplifiers fails due to gas discharge tubes (GDTs) becoming short circuits after power surges, disrupting communication paths and VoIP services during power outages, especially during storms when emergency services are needed.

Innovation Solution

Incorporating a gas discharge tube (GDT) that acts as an open circuit at low voltages and a short circuit at high voltages, with an electronic device, such as a fuse or relay, in series to maintain the non-interruptible communication path even if the GDT fails, ensuring continuous operation during power outages.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Object-affected harmful factors

If a gas discharge tube (GDT) is used for surge suppression, then surge protection capability is improved, but the GDT may become a permanent short circuit after a surge event, disrupting communication paths

Engineering Contradiction:
Improvesurge protection capabilityVSAvoidcommunication path continuity
Core Design Contradiction:
Object-affected harmful factorsVSReliability

Solution Approach 1:

A relay is introduced as an intermediary component between the GDT and the communication path. The relay acts as a mediator that can disconnect the GDT from the communication path when the GDT fails into a short circuit state, thereby protecting the communication path from disruption while maintaining the surge protection capability of the GDT.

Inventive Principle:
Principle #24Intermediary (Mediator)

Solution Approach 2:

The surge protection system is segmented into separate functional components: the GDT for surge suppression and the relay for path management. This segmentation allows the GDT to perform its surge protection function independently while the relay monitors and controls the connection to the communication path, enabling independent failure isolation.

Inventive Principle:
Principle #1Segmentation

2Object-affected harmful factors

If the GDT fails to a short circuit state, then surge protection is maintained, but the non-interruptible communication path is disrupted

Engineering Contradiction:
Improvesurge suppression functionVSAvoidemergency service availability
Core Design Contradiction:
Object-affected harmful factorsVSReliability

Solution Approach 1:

The relay serves as an intermediary that monitors the GDT's operational state and automatically disconnects the failed GDT from the communication path. This allows the system to maintain emergency communication services by removing the faulty component while preserving the overall surge protection architecture.

Inventive Principle:
Principle #24Intermediary (Mediator)

Solution Approach 2:

The relay is pre-configured to detect GDT failure conditions and automatically implement protective disconnection before the failure can propagate to disrupt the communication path. This beforehand cushioning prevents the short circuit from affecting the non-interruptible communication path.

Inventive Principle:
Principle #11Beforehand cushioning (Prior cushioning)

3Strength

If surge suppression circuitry is added to protect against power surges, then device protection is improved, but the complexity of the circuit increases

Engineering Contradiction:
Improvedevice protection capabilityVSAvoidcircuit complexity
Core Design Contradiction:
StrengthVSDevice complexity

Solution Approach 1:

The relay is introduced as a simple intermediary component that adds minimal circuit complexity while significantly enhancing device protection capability. The relay's straightforward switching mechanism provides robust protection without requiring complex control logic or additional active components.

Inventive Principle:
Principle #24Intermediary (Mediator)

Solution Approach 2:

The surge suppression circuitry is designed to be self-managing through the relay's automatic detection and disconnection capabilities. The system monitors its own operational state and automatically responds to failure conditions without requiring external intervention or complex control systems.

Inventive Principle:
Principle #25Self-service

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The solution ensures that RF communication paths remain operational during power outages, maintaining essential services like emergency VoIP services by preventing the GDT from becoming a permanent short circuit and providing redundant surge protection.

Implementation Method 1

A gas discharge tube (GDT), within the first circuit path, acts as an open circuit when a voltage across the GDT is less than a predetermined value and acts as a short circuit when the voltage across the GDT exceeds the predetermined voltage

Methodology Applied
Scientific EffectGas discharge: Townsend Discharge

Data Source

PatentUS10320342B2Advanced RF input port against surge
Publication Date: 2019.06.11 DIGICOMM INTERNATIONAL LLC
  • US10320342B2 patent drawing
  • US10320342B2 patent drawing
  • US10320342B2 patent drawing

AI summary

A bi-directional RF signal amplifier includes a RF input port and surge suppression circuitry downstream of the RF input port. First and second communications paths lead from the surge suppression circuitry to first and second RF output ports. The second communications path is considered non-interruptible and can support both downstream and upstream RF communications even in the absence of power being supplied to the RF signal amplifier. The surge suppression circuitry includes a data line connected to the RF input port. A first circuit path is electrically connected between the data line and ground. A gas discharge tube (GDT), within the first circuit path, acts as an open circuit when a voltage across the GDT is less than a predetermined value and acts as a short circuit when the voltage across the GDT exceeds the predetermined voltage. An electronic device is placed in series with the GDT within the first circuit path. The electronic device enables the second communications path of the RF signal amplifier to remain operable even if the GDT fails to a short circuit state due to a breakdown of the gases within the GDT.