Stacked I/O Connector Airflow Diverter for Heat Dissipation

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

High-density electronic systems with stacked transceivers face challenges in heat dissipation, leading to temperature rises that can cause errors and reduce component lifetime, especially when using high-power transceivers like QSFP-DD which consume up to 15 W of power.

Innovation Solution

A stacked I/O connector design with a housing channel and diverter configuration that promotes airflow through the cage, allowing air to flow between the interior and exterior, and directing it through openings to effectively dissipate heat from transceivers, even when transceivers are stacked closely together, without the need for a larger fan.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Quantity of substance

If transceivers are stacked in close proximity to increase density, then the quantity of transceivers per unit space increases, but heat dissipation becomes more difficult and temperature rises

Engineering Contradiction:
Improvequantity of transceiversVSAvoidtemperature of transceivers
Core Design Contradiction:
Quantity of substanceVSTemperature

Solution Approach 1:

The cage is divided into multiple channels (first channel, second channel, third channel) that segment the airflow path. Each channel can receive and cool transceivers independently, allowing multiple transceivers to be stacked closely while maintaining effective heat dissipation through dedicated airflow passages for each segment.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

A diverter is introduced as an intermediary component that redirects airflow from the second channel toward the first and third channels. This diverter mediates the airflow distribution, ensuring that cooling air reaches all transceiver locations even when stacked in close proximity, thereby resolving the heat dissipation issue while maintaining high density.

Inventive Principle:
Principle #24Intermediary (Mediator)

2Temperature

If conventional airflow paths are used in stacked connectors, then the structure remains simple, but heat dissipation efficiency is insufficient

Engineering Contradiction:
Improveheat dissipation efficiencyVSAvoidairflow path structure
Core Design Contradiction:
TemperatureVSDevice complexity

Solution Approach 1:

The airflow path is made dynamic through the diverter, which actively redirects airflow based on the needs of different channels. Instead of static, fixed airflow paths, the system uses the diverter to dynamically guide cooling air from the second channel to the first and third channels, improving heat dissipation efficiency while adding only moderate structural complexity.

Inventive Principle:
Principle #15Dynamics

3Temperature

If larger fans are used to improve heat dissipation, then temperature control improves, but the size and power consumption of the system increase

Engineering Contradiction:
Improvetemperature controlVSAvoidfan power consumption
Core Design Contradiction:
TemperatureVSUse of energy by moving object

Solution Approach 1:

The cooling system is segmented into multiple channels with dedicated airflow paths. This segmentation allows the existing fan to effectively cool multiple transceivers simultaneously by distributing airflow through separate channels, eliminating the need for larger or additional fans and maintaining energy efficiency while improving temperature control.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

The diverter acts as an intermediary that maximizes the utilization of airflow from the existing fan. By redirecting airflow from the second channel to the first and third channels, the diverter ensures that the fan's cooling capacity is fully utilized across all transceiver locations, achieving effective temperature control without increasing fan size or power consumption.

Inventive Principle:
Principle #24Intermediary (Mediator)

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The solution effectively limits the temperature rise of transceivers to less than 25 degrees C, even in an ambient environment of 25 degrees C, while maintaining efficient signal transmission and reception, and does so without increasing fan size or power consumption.

Implementation Method 1

The solution effectively limits the temperature rise of transceivers to less than 25 degrees C, even in an ambient environment of 25 degrees C... flowing air passing through the housing channels and through openings in a rear wall of the cage aligned with the housing channels, thereby dissipating heat from the transceivers

Methodology Applied
Scientific EffectConvection: Convection

Data Source

PatentUS11177592B2High performance stacked connector
Publication Date: 2021.11.16 AMPHENOL CORP
  • US11177592B2 patent drawing
  • US11177592B2 patent drawing
  • US11177592B2 patent drawing

AI summary

A shielded I/O connector that supports high density connections. The shielded connector has a cage with channels. At least a first channel is configured to receive a transceiver such that it may be plugged into a port in a connector housing at an end of the cage. At least a second channel is configured to dissipate heat by enabling air to flow adjacent the transceiver. The rate of air flow in the second channel is increased with a channel in the connector housing that connects with the second channel. Air may exit the housing channel through openings in rear surfaces of the cage or through openings that bound the housing channel.