Problem
Existing power supply substrates require large ground (GND) patterns for protective earth, leading to increased substrate size due to the need for minimal conductor dimensions, which complicates insulation between primary and secondary circuits.
Innovation Solution
The substrate design includes separate GND patterns for primary and secondary circuits with reinforced insulation between them, allowing for double insulation configurations that exclude the GND pattern from the protective bonding conductor, thereby reducing the need for enlarged GND patterns and preventing substrate size increase.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Reliability
If large GND patterns are provided for protective earth, then insulation between primary and secondary circuits is improved, but substrate size increases
Solution Approach 1:
The substrate is divided into distinct first and second regions separated by a partition wall, with the primary circuit in the first region and the secondary circuit in the second region. This segmentation provides electrical insulation between the circuits without requiring enlarged GND patterns, thereby maintaining reliability while preventing substrate size increase.
Solution Approach 2:
A partition wall is introduced as an intermediary structure between the primary and secondary circuits. This partition wall provides the necessary insulation and electrical separation, replacing the need for large GND patterns while maintaining the protective insulation function.
2Reliability
If minimal conductor dimensions are required for protective earth, then insulation distance is maintained, but device complexity increases
Solution Approach 1:
By segmenting the substrate into separate regions for primary and secondary circuits with a partition wall, the design simplifies the insulation configuration. The partition wall clearly defines the boundaries and insulation requirements, making the protective earth arrangement less complex while maintaining minimal conductor dimensions.
Data Source
AI summary
A substrate includes a primary circuit; a secondary circuit; and a ground (GND) patterns. In a path between the primary circuit and the secondary circuit without passing through the GND pattern, reinforced insulation is provided between the primary circuit and the secondary circuit. In a path between the primary circuit and the secondary circuit through the GND pattern, one of 1) a combination of reinforced insulation and functional insulation and 2) a combination of basic insulation, additional insulation, and functional insulation is provided between the primary circuit and the secondary circuit.