Surgical Knot Evaluation via Pressure Mapping

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Current methods for assessing surgical knot formation are subjective and lack objective feedback, making it difficult for surgeons and trainees to improve their knot-tying skills, especially in minimally invasive procedures where knot tension and distribution are critical to prevent complications like paravalvular leaks.

Innovation Solution

A system using a pressure sensor and controller to transform pressure data from surgically relevant objects into pressure maps, providing objective feedback on knot formation and tension distribution, which can be displayed for training and evaluation purposes.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Measurement precision

If subjective assessment methods are used for evaluating surgical knot formation, then the assessment process is simple and quick, but the measurement precision and reliability are poor

Engineering Contradiction:
Improveknot formation assessment accuracyVSAvoidevaluation system complexity
Core Design Contradiction:
Measurement precisionVSDevice complexity

Solution Approach 1:

The patent replaces subjective mechanical assessment (visual inspection by surgeons) with an automated sensor-based measurement system. Pressure sensors, load cells, and force sensors objectively measure knot tension, pressure distribution, and formation forces, eliminating human subjectivity and providing quantifiable data for knot evaluation.

Inventive Principle:
Principle #28Mechanics substitution (Replace mechanical system)

Solution Approach 2:

The patent introduces intermediary measurement devices (pressure sensors, load cells, force sensors) that mediate between the knot formation process and the assessment outcome. These sensors act as intermediaries that translate physical knot characteristics into measurable signals, enabling objective evaluation without direct human intervention in the measurement process.

Inventive Principle:
Principle #24Intermediary (Mediator)

2Reliability

If objective feedback systems are implemented, then the reliability of knot formation evaluation is improved, but the device complexity increases

Engineering Contradiction:
Improveknot formation evaluation reliabilityVSAvoidevaluation system complexity
Core Design Contradiction:
ReliabilityVSDevice complexity

Solution Approach 1:

The patent implements feedback mechanisms where sensor measurements of knot tension and pressure are processed and compared against optimal values. The system provides real-time or post-operative feedback to surgeons about their knot-tying performance, enabling continuous improvement and consistent quality while maintaining reliable objective assessment.

Inventive Principle:
Principle #23Feedback

Solution Approach 2:

The evaluation system is designed to autonomously perform measurements and assessments without requiring external expert intervention. The sensors automatically detect knot characteristics, the processor analyzes the data, and the system generates evaluations independently, making the reliable assessment process self-sufficient and reducing operational complexity.

Inventive Principle:
Principle #25Self-service

3Measurement precision

If multiple sensors and measurement devices are used to capture comprehensive knot data, then the measurement precision is improved, but the ease of operation deteriorates

Engineering Contradiction:
Improvepressure and tension measurement accuracyVSAvoidsystem operation simplicity
Core Design Contradiction:
Measurement precisionVSEase of operation

Solution Approach 1:

The patent combines multiple measurement functions (pressure sensing, force measurement, tension detection) into an integrated evaluation system. Multiple sensors are merged into a coordinated measurement network that collectively assesses knot formation, reducing the operational burden of managing separate devices while maintaining comprehensive measurement precision.

Inventive Principle:
Principle #5Merging (Combining)

Solution Approach 2:

The evaluation system is designed with multi-functional capabilities that allow a single integrated system to perform various knot assessment tasks. The sensor array and processing unit can evaluate different knot types, tension levels, and pressure distributions using the same hardware platform, simplifying operation while providing precise multi-parameter measurement.

Inventive Principle:
Principle #6Universality (Multi-functionality)

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

The system offers a reliable and reusable method for evaluating surgical knot formation, enabling objective assessment and improving knot-tying skills, thereby reducing the risk of complications such as paravalvular leaks by providing immediate and accurate feedback.

Implementation Method 1

a pressure sensor...transform signals from the pressure sensor into a pressure map having pressure magnitudes from a plurality of locations on the pressure sensor

Methodology Applied
Scientific EffectPressure sensing:

Data Source

PatentUS9667884B2System and method for evaluating surgical knot formation
Publication Date: 2017.05.30 LSI SOLUTIONS INC
  • US9667884B2 patent drawing
  • US9667884B2 patent drawing
  • US9667884B2 patent drawing

AI summary

A system for evaluating surgical knot formation is disclosed. The system includes a first surgically relevant object, a pressure sensor, and at least one pair of suture ends passing through the pressure sensor and the first surgically relevant object. The system also includes a controller coupled to the pressure sensor and configured to 1) transform signals from the pressure sensor into a pressure map having pressure magnitudes from a plurality of locations on the pressure sensor corresponding to one or more knots which may be formed in the at least one pair of suture ends; and 2) format the pressure map for display.