Vacuum Mounting Flow Control for Epoxy Void Filling

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Conventional vacuum systems face challenges in effectively filling voids and cracks in material specimens during cold mounting due to air pressure within these voids, which hinders the encapsulation of delicate and friable samples in epoxy resin.

Innovation Solution

A vacuum system with a flow control device featuring a dispensing knob and sheath that pinches the dispensing tube to control epoxy resin flow, allowing for precise regulation of fluid flow through varying channel depths and positions, facilitating efficient epoxy resin distribution under vacuum conditions.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Manufacturing precision

If vacuum conditions are applied to remove trapped air from voids, then the epoxy resin can penetrate into pores and cracks, but the air pressure within voids hinders effective filling

Engineering Contradiction:
Improvevoid filling qualityVSAvoidair pressure in voids
Core Design Contradiction:
Manufacturing precisionVSObject-affected harmful factors

Solution Approach 1:

The system applies periodic vacuum cycles to progressively remove air from voids. By alternating vacuum application with resin infusion, the system creates periodic pressure differentials that force air out of deep pores and cracks over multiple cycles, overcoming the initial air pressure barrier.

Inventive Principle:
Principle #19Periodic action

Solution Approach 2:

The system utilizes pressure phase transitions by cycling between vacuum (low pressure) and atmospheric/positive pressure (high pressure) states. During vacuum phases, air is extracted from voids; during pressure phases, epoxy resin is forced into the now-empty void spaces, achieving complete penetration.

Inventive Principle:
Principle #36Phase transitions

2Quantity of substance

If epoxy resin is poured under vacuum conditions, then voids are filled, but controlling the flow rate and distribution of resin is difficult

Engineering Contradiction:
Improveepoxy resin distributionVSAvoidflow control
Core Design Contradiction:
Quantity of substanceVSEase of operation

Solution Approach 1:

The flow control device features a movable dispensing knob with variable depth positioning. The operator can dynamically adjust the knob depth during the resin pouring process to modulate the opening size, thereby controlling the flow rate and distribution of epoxy resin in real-time according to the specimen's needs.

Inventive Principle:
Principle #15Dynamics

Solution Approach 2:

The system changes the physical parameter of the dispensing opening by varying the depth position of the dispensing knob. This parameter adjustment directly controls the flow characteristics of the epoxy resin, enabling precise regulation of quantity and distribution without complex additional mechanisms.

Inventive Principle:
Principle #35Parameter changes

3Ease of operation

If a simple pouring method is used, then the process is easy to operate, but the flow of epoxy resin is inconsistent and uncontrolled

Engineering Contradiction:
Improvepouring process simplicityVSAvoidresin flow consistency
Core Design Contradiction:
Ease of operationVSManufacturing precision

Solution Approach 1:

The flow control device segments the pouring process into controllable stages through the dispensing knob mechanism. The knob can be positioned at different depths to create distinct flow regimes, allowing the operator to divide the resin infusion into controlled portions rather than a single uncontrolled pour.

Inventive Principle:
Principle #1Segmentation

Solution Approach 2:

The dispensing knob acts as an intermediary device between the epoxy resin reservoir and the specimen. It mediates the flow by providing a variable restriction that the operator can adjust, thereby controlling the resin delivery without requiring direct manual pouring while maintaining operational simplicity.

Inventive Principle:
Principle #24Intermediary (Mediator)

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

This solution enhances the encapsulation of material samples by ensuring consistent and controlled epoxy resin flow into voids and cracks, improving the retention and support of sensitive specimens during testing.

Implementation Method 1

Cold mounting vacuum systems pour an epoxy resin over a material sample in vacuum (or near vacuum) conditions. The vacuum conditions help to remove trapped air from the voids.

Methodology Applied
Scientific EffectVacuum: Vacuum

Implementation Method 2

A vacuum system with a flow control device featuring a dispensing knob and sheath that pinches the dispensing tube to control epoxy resin flow, allowing for precise regulation of fluid flow through varying channel depths and positions

Methodology Applied
Scientific EffectFluid flow control:

Implementation Method 3

Subsequent curing at increased pressures will force or push the resin into the voids.

Methodology Applied
Scientific EffectPressure: Pressure Increase

Data Source

PatentEP3941848B1Fluid flow control of vacuum mounting systems
Publication Date: 2024.11.27 ILLINOIS TOOL WORKS INC
  • EP3941848B1 patent drawingFigure 1A~1B
  • EP3941848B1 patent drawingFigure 2A~2B
  • EP3941848B1 patent drawingFigure 3A

AI summary

System and methods for mounting of material samples via a vacuum system (100) and controlling fluid flow through a tube of the vacuum system (100) are disclosed. In some examples, the vacuum system (100) may be a castable and/or cold mounting vacuum system (100) that facilitates mounting and/or encapsulation of material samples in epoxy resin under low, vacuum, and/or near vacuum pressure. In some examples, the vacuum system (100) may comprise a flow control device (500) configured to control epoxy flow through a dispensing tube that connects to a hollow vacuum chamber (104). In some examples, the vacuum chamber (104) may have an opening (134) defined by a rim (130) sandwiched between upper and lower portions of a sealing ring (132). A movable lid (136) may be configured to press down on the upper portion of the sealing ring (132) when in a closed position, so as to seal the opening (134).