Problem
Tightly sealed homes can lead to depressurization, causing gas-fired appliance combustion products to spill back into the home due to back drafting, which existing systems fail to address effectively, especially when cold air enters through the venting system.
Innovation Solution
A vent proving system that monitors vent gas temperature using a sensor and controller to detect back draft conditions, operating an electrical switch to adjust the vent damper and ensure proper ventilation by shutting off the gas burner if a back draft is present.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Loss of energy
If homes are sealed tighter to reduce air leakage, then energy efficiency is improved, but depressurization occurs causing back drafting of combustion products into the home
Solution Approach 1:
The vent proving system performs preliminary verification of proper venting operation before allowing the gas burner to operate. The controller checks that the vent damper is in the correct position and that venting conditions are adequate prior to ignition, preventing back drafting from occurring in the first place
Solution Approach 2:
The system continuously monitors venting conditions through sensors that detect draft pressure, damper position, and other parameters. This feedback is sent to the controller which can adjust damper position or shut down the burner if back drafting conditions are detected, resolving the contradiction between sealed construction and safe combustion
2Reliability
If a thermal switch is used to shut off the boiler when drafting is blocked, then vent blocking is addressed, but back drafting from cold air entering through the vent is not detected
Solution Approach 1:
The vent proving system performs multiple functions: it detects both physical vent blocking and back drafting conditions caused by cold air infiltration. The combination of draft sensors, temperature sensors, and damper position sensors provides comprehensive monitoring that addresses both types of hazardous conditions with a single integrated system
3Object-affected harmful factors
If the vent damper is opened when the gas burner is on, then proper venting is achieved, but latent heat is lost when the damper closes
Solution Approach 1:
The vent damper is designed as a dynamic three-position device rather than a simple on/off damper. It can remain partially open to maintain a thermal seal while still providing adequate venting, or adjust its position based on real-time conditions. This dynamic adjustment allows the system to maintain heat retention when possible while ensuring safe venting when required
Applied Scientific Principles
This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.
Function Achieved in This Case
Prevents combustion products from spilling into the home by effectively identifying and correcting back draft conditions, ensuring safe and efficient operation of gas-fired appliances.
Implementation Method 1
a sensor for sensing a variable in the vent representing air flow direction in the vent
Implementation Method 2
The controller determines if a back draft condition is present in the vent when the gas burner is on
Data Source
AI summary
A vent proving system is described for use with a gas fired appliance. The gas fired appliance includes a gas burner, a vent damper for selectively opening or closing an exhaust vent from the gas fired appliance and a relay control for operatively controlling the vent damper and the gas burner to open the damper if the gas burner is on. The vent proving system comprises a sensor for sensing a variable in the vent representing air flow direction in the vent. An electrical switch is connected in series between the relay control and the vent damper. A controller is operatively connected to the sensor, the electrical switch and to the relay control. The controller determines if a back draft condition is present in the vent when the gas burner is on and selectively operates the electrical switch to open the connection between the relay control and the vent damper if a back draft condition is present in the vent when the gas burner is on.