Ventilator Display Segmentation for Usability
Find Innovative SolutionsGenerate Solutions
Solution Overview
Problem
Medical ventilators with small displays face challenges in setup, configuration, and viewing current status due to limited display capabilities, making them difficult to use effectively.
Innovation Solution
A medical ventilator system with a touch-sensitive display and a controller that enables a larger remote display via a unitary display coupler, providing power, video, and control signals, and generating different graphical user interfaces for local and remote displays based on coupling status.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Weight of stationary object
If a small display is used in the medical ventilator, then the size and weight of the ventilator are reduced, but the display capability and ease of operation deteriorate
Solution Approach 1:
The display system is segmented into two independent parts: a small local display integrated into the ventilator for portability, and a separate remote display device that can be connected when needed. This allows the ventilator to maintain its lightweight design while providing access to a larger display interface for setup and monitoring operations.
Solution Approach 2:
A display interface with a unitary display coupler acts as an intermediary between the ventilator controller and the remote display device. This intermediary component enables communication and data transfer between the two displays, allowing the small local display to function as a remote display when the larger remote display is not available.
2Weight of stationary object
If a small display is used in the medical ventilator, then the size and weight of the ventilator are reduced, but the ability to view current status deteriorates
Solution Approach 1:
The display system is segmented into two independent parts: a small local display integrated into the ventilator for portability, and a separate remote display device that can be connected when needed. This allows the ventilator to maintain its lightweight design while providing access to a larger display interface for setup and monitoring operations.
3Device complexity
If a small display is used in the medical ventilator, then the device complexity is reduced, but the productivity deteriorates due to time consumption
Solution Approach 1:
The display system is segmented into two independent parts: a small local display integrated into the ventilator for portability, and a separate remote display device that can be connected when needed. This allows the ventilator to maintain its lightweight design while providing access to a larger display interface for setup and monitoring operations.
Solution Approach 2:
The controller is pre-configured with the capability to detect and communicate with remote display devices, and the display interface is pre-established with a unitary coupler. When a remote display becomes available, the system can quickly switch to using it without requiring complex reconfiguration, thus improving setup speed.
4Ease of manufacture
If a small display is used in the medical ventilator, then the manufacturing cost is reduced, but the adaptability deteriorates
Solution Approach 1:
The display interface is designed with universal functionality to work with both the integrated local display and external remote display devices. The controller can detect the presence of a remote display and automatically adapt its output, and the unitary display coupler provides a universal connection interface that accepts various display devices, making the system versatile without requiring complex manufacturing.
Data Source
AI summary
A medical ventilator (100, 200) including a first user interface (114) having a touch-sensitive display having a display area; and at least one controller (104) which determines whether a second user interface (122, 222) having a touch-sensitive display is coupled to the medical ventilator, enables the first user interface when it is determined that the second user interface is not coupled to the medical ventilator, and enables the second user interface when it is determined that the second user interface is coupled to the medical ventilator.