Problem
Current distributed power generation systems face inefficiencies in utilizing local generators and providing uninterrupted power, as they often rely on emergency generators that are idle most of the time and lack flexibility, leading to suboptimal return on investment and potential power outages due to synchronization issues and frequency fluctuations.
Innovation Solution
A method involving a controller that monitors the main distribution network for potential faults, allowing pre-emptive configuration of local group distribution networks as virtual islands, matching power sources with loads, and enabling smooth transitions to islanded states, thereby maintaining power stability and reducing frequency and voltage deviations.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Reliability
If emergency generators are provided to ensure power supply during outages, then security of supply is improved, but device complexity and cost increase due to idle equipment and changeover switches
Solution Approach 1:
The controller pre-configures virtual islands by proactively identifying critical loads and assigning them to specific generators before outages occur. This preliminary configuration enables immediate power restoration without requiring changeover switches or idle emergency generators, as the system is already organized for rapid reconfiguration when faults occur.
Solution Approach 2:
The system creates virtual copies of power distribution configurations through software-defined virtual islands. Instead of physical duplicate emergency generator systems, the controller creates virtual representations of power islands that can be rapidly instantiated through software control, eliminating the need for physical changeover switches and reducing hardware complexity.
2Object-affected harmful factors
If the distribution system trips off the whole network during fault conditions, then safety is maintained, but power supply reliability deteriorates as all generators go offline
Solution Approach 1:
The controller segments the distribution network into multiple virtual islands, each comprising critical loads and their assigned generators. When faults occur, only affected segments are isolated while other virtual islands continue operating independently. This segmentation allows the system to maintain safety by isolating faults while preserving power supply reliability through continued operation of unaffected segments.
Solution Approach 2:
The controller acts as an intermediary that manages the transition between grid-connected and islanded modes. It monitors system conditions and orchestrates the formation of virtual islands, enabling smooth transitions that maintain both safety and reliability. The controller mediates between the main distribution network and local generators, coordinating power flow and synchronization to prevent harmful effects while ensuring continuous supply.
3Ease of operation
If generators operate in island conditions with simple frequency droop control, then ease of operation is improved, but power system stability and flexibility deteriorate
Solution Approach 1:
The controller implements closed-loop feedback control that continuously monitors frequency, voltage, and load conditions across the distribution network. This feedback enables the system to maintain stability by dynamically adjusting generator output based on real-time conditions. The feedback mechanism allows generators to operate in island mode with enhanced stability, as the controller compensates for disturbances and maintains synchronization without requiring complex manual control.
Solution Approach 2:
The controller provides multi-functional capabilities, combining simple frequency droop control with advanced synchronization and load management functions. This universal control approach allows the same controller to handle both simple islanded operation and complex grid-connected scenarios, maintaining ease of operation while enhancing power system stability through intelligent coordination of multiple generators and loads.
4Stability of the object's composition
If local group distribution networks are pre-configured as virtual islands, then transition smoothness is improved, but control complexity increases
Solution Approach 1:
The controller implements self-service functionality by automatically configuring virtual islands based on pre-defined critical load priorities and generator capabilities. When outages occur, the system self-organizes without requiring manual intervention, automatically matching generators to critical loads and establishing virtual islands. This self-service approach reduces control complexity by eliminating the need for manual pre-planning while maintaining smooth transitions through automated configuration.
Data Source
Figure 1
AI summary
Distributed power generation systems generally comprise a number of power sources and electrical power loads interconnected by a distribution network. Electrical switches and fuses are provided such that local groups of power sources and power loads can be established. Should there be a degradation in the distribution network in terms of a set of criteria such as electrical frequency, current or voltage then the switch or fuse may be thrown to establish each local group as an island. By monitoring divergence from a set of criteria a method and controller may be utilised whereby the distribution network as a whole is considered and configured to establish virtual islands which operate prior to the establishment whether inadvertently or deliberately of actual islands within the distribution network. In such circumstances the transition from normal operation for the distribution network to islanded operation for the distribution network is less severe.