Boost Circuit for Energetic Fire Voltage Regulation
Solution Overview
Problem
Energetic systems require maintaining an All-Fire voltage over their life cycle without periodic testing or maintenance, posing challenges in reducing size and cost while ensuring reliability and longer shelf life, especially in designs with small footprints and cost sensitivity.
Innovation Solution
Implementing a boost circuit controlled by system logic to increase voltage to the energetic fire circuit only when required, using a boost converter or capacitive voltage multiplier, which allows for lower system voltage and reduced power consumption, enhancing safety and extending the power source's usable lifetime.
Engineering Contradictions & Design Principles
Engineering Contradiction Analysis
1Volume of moving object
If the power source voltage is reduced to meet size and cost requirements, then the device size and cost are reduced, but the All-Fire voltage requirement for the energetic fire circuit cannot be met
Solution Approach 1:
The system dynamically adjusts voltage by introducing a boost circuit that converts a lower operating voltage (e.g., 3V) to a higher All-Fire voltage (e.g., 12V) only when needed for the energetic fire circuit. This allows the power source to be sized for the lower operating voltage while still meeting the higher voltage requirement temporarily for fire circuit activation.
Solution Approach 2:
The patent changes the voltage parameter over time and operating conditions. The system operates at a lower voltage during normal operation to reduce power consumption and size, then transforms to a higher voltage state when the energetic fire circuit needs to be activated, ensuring both size reduction and reliability are achieved.
2Ease of manufacture
If the power source capacity is reduced to lower cost, then the device cost is reduced, but the power source cannot maintain sufficient voltage throughout the device life
Solution Approach 1:
The boost circuit operates periodically or on-demand rather than continuously. It activates only when the energetic fire circuit requires the higher All-Fire voltage, allowing the power source to be smaller and lower capacity while still meeting voltage requirements when needed. This periodic operation reduces overall power consumption and extends power source life.
3Use of energy by moving object
If the system operates at lower voltage to reduce power consumption, then power requirements are reduced, but the energetic fire circuit cannot receive the required All-Fire voltage
Solution Approach 1:
The boost circuit acts as an intermediary device between the low-voltage power source and the high-voltage energetic fire circuit. It converts the lower operating voltage to the required All-Fire voltage when needed, allowing the system to operate at lower power consumption during normal operation while ensuring sufficient voltage for fire circuit activation when required.
Applied Scientific Principles
This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.
Function Achieved in This Case
Ensures the All-Fire voltage is available when needed, reduces power requirements, increases safety, and extends the life of the power source by powering down the fire circuit until activation, while maintaining reliability and meeting design objectives of smaller size and lower cost.
Implementation Method 1
a boost circuit to increase a voltage provided by the power source to at least the All-Fire voltage
Implementation Method 2
using a boost converter or capacitive voltage multiplier
Data Source
AI summary
Energetic firing device using a boost circuit to ensure an energetic fire circuit is charged to an All-Fire voltage even if a power source is not capable of providing necessary voltage. Boost circuit may be located between power source and energetic fire circuit and increase voltage provided by the power source when enabled. Boost circuit may be located between system logic and the energetic fire circuit and generate the All-Fire voltage when enabled. The boost circuit may generate the All-Fire voltage from an enable signal and a pulse train provided by the system logic. The boost circuit may be a switching power supply that may regulate the All-Fire voltage generated. The boost circuit may be a capacitive voltage multiplier. The boost circuit may remove power from being provided to the energetic fire circuit until enabled thus reducing system power and increasing safety.