CMP Platen Temperature Control for Stable Removal Rates

Resolve Bottlenecks,
Find Innovative Solutions
Generate Solutions

Solution Overview

Problem

Current chemical mechanical polishing systems face challenges in maintaining precise platen temperature control, leading to suboptimal removal rates and fluid breakdown during semiconductor substrate manufacturing, especially with narrower line widths requiring tighter temperature control.

Innovation Solution

A chemical mechanical polishing system incorporating a platen temperature control system with a PID controller, fluid controller, and heat exchanger, which senses the polishing surface temperature and adjusts coolant flow through channels in the platen to maintain the temperature within a predefined operational window.

Engineering Contradictions & Design Principles

VSEngineering Contradiction Analysis

1Productivity

If platen temperature is increased to improve removal rate, then polishing productivity increases, but polishing fluid breaks down yielding unacceptable results

Engineering Contradiction:
Improveremoval rateVSAvoidpolishing result quality
Core Design Contradiction:
ProductivityVSReliability

Solution Approach 1:

The system employs a temperature sensor to continuously monitor the polishing surface temperature and feeds this information back to a PID controller. The controller adjusts the coolant flow rate dynamically based on the temperature feedback, ensuring the temperature remains within the operational window and preventing fluid breakdown while maintaining optimal removal rates.

Inventive Principle:
Principle #23Feedback

Solution Approach 2:

The system changes the coolant flow rate parameter dynamically in response to temperature variations. By adjusting this parameter, the system maintains the polishing surface temperature within the narrow operational window, preventing both insufficient removal rates and fluid breakdown.

Inventive Principle:
Principle #35Parameter changes

2Reliability

If platen temperature is decreased to prevent fluid breakdown, then polishing fluid stability improves, but removal rate becomes unacceptably low

Engineering Contradiction:
Improvepolishing fluid stabilityVSAvoidremoval rate
Core Design Contradiction:
ReliabilityVSProductivity

Solution Approach 1:

The temperature sensor continuously monitors the polishing surface temperature and provides feedback to the PID controller. When temperature drops below the operational window, the controller reduces coolant flow to prevent excessive cooling, thereby maintaining sufficient removal rates while preventing fluid breakdown.

Inventive Principle:
Principle #23Feedback

Solution Approach 2:

The system transitions from static temperature control to dynamic control by continuously adjusting coolant flow based on real-time temperature conditions. This dynamic adjustment allows the system to optimize both removal rate and fluid stability under varying operational conditions.

Inventive Principle:
Principle #15Dynamics

3Measurement precision

If PID control with dynamic coolant adjustment is implemented to maintain precise temperature, then temperature control precision improves, but device complexity increases

Engineering Contradiction:
Improvetemperature control precisionVSAvoidcontrol system complexity
Core Design Contradiction:
Measurement precisionVSDevice complexity

Solution Approach 1:

The PID controller receives continuous temperature feedback from the sensor and automatically adjusts coolant flow without requiring manual intervention. This automated feedback loop achieves precise temperature control while minimizing the need for complex manual control mechanisms.

Inventive Principle:
Principle #23Feedback

Solution Approach 2:

The control system is self-regulating, using the temperature sensor and PID controller to automatically adjust coolant flow based on actual temperature conditions. This self-service capability reduces the need for external monitoring and manual adjustment, simplifying overall system operation despite the added control components.

Inventive Principle:
Principle #25Self-service

Applied Scientific Principles

This section explains which scientific principles are used to turn an abstract innovation direction into a practical engineering solution.

Function Achieved in This Case

This solution ensures stable polishing rates by maintaining the polishing surface temperature within a defined range, preventing fluid breakdown and enhancing the precision and reliability of semiconductor substrate fabrication.

Implementation Method 1

a heat exchanger. The flow controller is configured to control an amount of fluid provided from the heat exchanger to channels of the platen

Methodology Applied
Scientific EffectHeat transfer: Heat Exchanger

Implementation Method 2

The platen temperature control system includes a PID controller, a fluid controller, and a heat exchanger. The flow controller is configured to control an amount of fluid provided from the heat exchanger to channels of the platen in response to instructions provided by the PID controller

Methodology Applied
Scientific EffectFeedback control: Feedback

Data Source

PatentUS11911869B2Chemical mechanical polishing system with platen temperature control
Publication Date: 2024.02.27 APPLIED MATERIALS INC
  • US11911869B2 patent drawing
  • US11911869B2 patent drawing
  • US11911869B2 patent drawing

AI summary

Embodiments of a system and method for polishing substrates are provided. In one embodiment, a polishing system is provided that includes a polishing module having a platen, and a platen temperature control system. The platen temperature control system includes a PID controller, a fluid controller, and a heat exchanger. The flow controller is configured to control an amount of fluid provided from the heat exchanger to a channels of the platen in response to instructions provided by the PID controller.