Segmented driving and following motors synchronize to eliminate tendon slack during endoscopy instrument actuation.
A support member partitions the endoscope operation section into separate spaces for angle wires and internal components.
A split-type capsule uses external magnetic fields to rotate internal windows and release medication.
Segmented brake parts engage operation units to resolve force distribution contradictions and eliminate noise during manual adjustment.
Variable-length sequence segmentation aligns captured video with templates, resolving misalignment errors caused by irregular gastrointestinal motility speeds.
A coupling device attaches to a robotic endoscope and secures microwave energy cables.
A planar imaging module mounts light-emitting diodes and a solid-state image sensor on a single support substrate to deliver compact optical detection.
Segmented strain relief elements in void regions protect electrical cables from damage while navigating tortuous paths.
A peripheral light reduction stop shields oblique rays to reduce brightness saturation in ultrasonic endoscopes.
A medical image processing device generates identification images to mark specific positions within captured frames.
Actively movable light reflector directs polymerization beam or camera sensor in single dental handpiece.
A constant horizon mechanism constrains a visualization device's rotation about its own axis while allowing the end effector to rotate freely.
Rotating dial aligns flexion switches with joint orientation, eliminating directional confusion during rotation.
A surgical instrument coupling device uses roller elements to enable smooth sliding along an elongate insertion shaft.
Segmented irrigation channels penetrate the transporter latch system to flush contaminants and ensure sterility.
A handheld surgical apparatus uses a deployable probe and blade to locate and cut targeted anatomical structures with precision.
A pipette calibration managing system centralizes electronic data to automate maintenance scheduling and track usage status across laboratory equipment.
A movable electrode ablation cap fits onto an endoscope to deliver controlled energy to tissue sites.
Dual comb ranging determines fiber spacing to prevent damage during laser therapy.
Detect piezoelectric actuator voltages to estimate cantilevered optical fiber position, compensating for inconsistent drive responses.
A multipurpose medical image indicator integrates fluorophores and contrast agents into a rubber matrix to enable real-time lesion visualization.
A detachable locking mechanism and flushing connection enable easy cleaning of the instrument shaft while maintaining stability during endoscopic procedures.
An infrared observing system visualizes deep tissue blood flow using dual-wavelength light and an absorbing pigment.