See how an ejector system uses motive fluid to compress suction flow, enabling heat pumps to op
See how a secondary circulation system isolates hydrocarbon refrigerants in dishwasher heat rec
See how a partitioned condenser with a colder condensation surface enriches and removes foreign
See how a dual-circuit heat pump with intermediary refrigerant recovers exhaust air energy to p
See how a branching bypass passage with heat absorption stabilizes refrigerant state and boosts
See how dynamic indoor fan speed adjustment based on outdoor coil temperature and compressor sp
See how thermal insulation, heat pump recovery, and feedback control reduce diffusion pump ener
See how an interlaced outdoor heat exchanger with multiple refrigerant flow paths enables local
See how a partition wall in an integrated heat pump module suppresses heat transfer between hig
See how priority-based periodic switching between hot water production and air conditioning mod
See how periodic compressor cycling and electrical heating elements maintain hot water producti
See how segmented expansion units and mode-based control minimize refrigerant flow instability
See how a ternary HFO-HFC refrigerant blend achieves GWP below 150 and Class A1 safety while ma
See how a cascade heat pump defrosts by reversing first-stage refrigerant flow while a bypass l
See how frequency-based control with superheat feedback corrects expansion valve opening to pre
See how a cascade heat pump defrost method reverses first-stage flow while bypassing the second
See how pressure-based reversing valve control blocks compressor discharge flow during defrost
See how replacing an expansion valve with a rotatable expander unit enables a heat cycle system
See how a secondary evaporator with hot-fluid supply boosts refrigerant temperature in low-ambi
See how synchronized 4/2-way directional control valves reverse heat-exchanger flow without add
See how supercooling degree measurement detects small R290 refrigerant leaks despite low satura
See how internal and external adsorbers reduce refrigerant concentration without pressure build
See how a plastic accumulator with vertical and horizontal baffles separates refrigerant phases
See how segmented outdoor heat exchangers with dual four-way valves direct high-temperature ref
See how a heat pump transfers heat from wastewater to incoming fresh water, achieving 300-600%
See how a two-stage compression heat pump with water droplet intercooling achieves 280°C output
See how a heat pump transfers heat from wastewater to fresh water using refrigerant circulation
See how buried pipe thermal storage and dual heat exchange modules capture data center waste he
See how an exhaust heat exchanger recovers thermal energy from facility air and transfers it to
See how a rotatable inner housing with selective penetration holes merges heat pump, battery, a
See how a dual-circuit heat pump uses dynamic refrigerant redistribution to match actual operat
See how a dual circuit heat pump replaces mechanical vapor compression with liquid CO2 pumping
See how elongated support structures and compression stress control prevent SMA material buckli
See how a capacitor-based backup power circuit enables valve closure during power failures to p
See how a dual-portion heat pipe transfers power converter waste heat into the refrigeration cy
See how dual gas and liquid injection valves dynamically adjust refrigerant flow to prevent com
See how a reinforcement learning agent dynamically optimizes water loop temperature and flow ra
See how a connection kit with regulating valves and bypass portions prevents refrigerant and oi
See how a selectable bypass flow path routes refrigerant directly from compressor to accumulato
See how segmented thermal storage systems enable a single heat pump to release high-temperature
See how modular housing with gas separator and exhaust duct prevents hazardous refrigerant leak
See how integrating the preheating chamber with the pump body eliminates the regenerator, preve
See how an HFO-1233zd blend achieves GWP below 150 while enabling condensing temperatures above
See how segregated chambers with controlled ventilation isolate flammable refrigerant leaks fro
See how a seed crystal chamber uses directional freezing and thermal conductivity differences t
See how a bypass circuit with an evaporative heat exchanger suppresses excessive refrigerant fl
See how a valve opening circuit uses external DC power to open refrigerant valves after AC disc
See how integrating a heat pump with thermochemical storage eliminates external heat sources, a
See how separated chambers with directed ventilation isolate flammable refrigerant from electro
A grid-protected heat exchanger uses natural water flow for heat recovery without pumps, reducing clogging, damage, and energy loss.
Using Z-HFO-1336mzz as the working fluid lets high-temperature heat pumps reach higher condenser temperatures with lower GWP and zero ODP.
Recycled condensation heat vaporizes and compresses a secondary heating agent to cut Rankine-cycle losses and reduce external cooling demand.
Gradually varied louver spacing redirects airflow to delay front-side frosting, reduce defrost cycles, and sustain heat pump heating efficiency.
A controller tracks available heat pump capacity during defrost and adjusts active units to match thermal load with less energy waste.
A recirculation loop cools working fluid from an electrochemical climate control unit, rejecting heat without a condenser and limiting fluid temperature.
Dynamic condensing temperature control keeps the heat pump just above fluid temperature to improve COP and cut CO2 emissions.
A modified booster circuit manages refrigerant flow to deliver high-temperature water efficiently in low-air and domestic hot water operation.
Two expansion valves keep refrigerant low-density in the transit duct, cutting charge while preserving heat pump range and performance.
Conventional pumps and compressors waste energy changing fluid pressure; feedback-controlled pressure exchange recovers energy and adjusts pump speed.
A controlled gas barrier prevents hot-cold fluid mixing, improving SMA/NTE power and heat-pump cycle efficiency.
Optimizing suction-side flow path length to ensure homogeneous refrigerant mixing before compressor entry.
A heat pump cycle device uses a bypass flow-rate adjusting unit to manage refrigerant pressure differences.
A reversible heat pump uses a dual hydraulic circuit to feed utility liquid through a cooling device before a condenser.
Independent tube bundles in one shell resolve the contradiction between versatility and complexity, reducing space requirements.
A variable-frequency heat pump water heater adjusts compressor operation based on grid-connected photovoltaic surplus electricity.
A geothermal adapter uses zeolite to absorb moisture and release latent heat, enhancing thermal transfer in cold climates.