Embodiment 1
[0038] Embodiment 1, the adsorption of natural hydrotalcite to methyl orange:
[0039] Firstly, methyl orange was selected as the indicator, and hydrotalcite was used as the inorganic adsorbent. A 1.0 g / L methyl orange solution and a 30.0 g / L hydrotalcite suspension were preliminarily prepared for subsequent experiments (in this experiment, the Color agent + pH buffer solution beaker 2).
[0040]Standard curve: take a 1L beaker as the adsorption mixture beaker 1, use 1L deionized water as the blank control, add 1mL, 2mL, 3mL, 4mL, 5mL of 1g / L methyl orange solution into the deionized water respectively, and place in Stir on a digital temperature-controlled magnetic stirrer, send the solution into the online spectrophotometer 7 through the peristaltic pump 5, record the experimental data of each group, and draw a standard curve of absorbance and time according to the data.
[0041] Concentration of hydrotalcite suspension: choose 4mL of 1g / L methyl orange solution, add 2 mL of...
Embodiment 2
[0049] Embodiment 2, the adsorption of bentonite to europium:
[0050] 1. Experiment preparation and standard curve drawing:
[0051] Carry out preliminary preparations, connect the equipment, prepare two 1L beakers, add europium solution to the adsorption mixture beaker 1 to adjust the pH to 3.5, add acetic acid-sodium acetate and arsenazo to the chromogenic agent + pH buffer solution beaker 2 Ⅲ, turn on the peristaltic pump 5 (25 rpm) and simultaneously pass the solution and deionized water in the color developer + pH buffer solution beaker 2, and make them merge through the tee, and put the adsorption mixed solution beaker 1 and the color developer The mixed solution in the +pH buffer solution beaker 2 is introduced into the temperature adjustment heating tank 8 for heating, and the temperature adjustment heating tank 8 is set at a temperature of 30 degrees Celsius, and the europium solution (1, 2, 3, 4, 5 mL) to determine the absorbance value and draw a standard curve.
...