Test method for compositions of fine silica powder
A high-purity quartz sand, component detection technology, applied in the direction of removing a certain component and weighing, etc., can solve the problems of cumbersome analysis process, high main content analysis results, low analysis results, etc., to improve analysis efficiency and analysis steps. The effect of simplifying and improving efficiency
- Summary
- Abstract
- Description
- Claims
- Application Information
AI Technical Summary
Problems solved by technology
Method used
Image
Examples
Embodiment 1
[0024] (1) Dry the quartz sand sample in a 105°C oven to constant weight in advance to remove the influence of moisture.
[0025] (2) Place the platinum crucible on the electric furnace with constant weight. Transfer to a desiccator for later use. Note its weight m1.
[0026] (3) Weigh 1.0000g of the dried quartz sand sample into the platinum crucible that has been treated with constant weight, and record the sample weight m0. Wet the sample with a small amount of water and add 5 drops of 50% H by volume 2 SO 4 , add 40ml HF (concentrated), and add 2ml 50% volume concentration of HNO 3 Solution to help dissolve. Heat on the electric stove at low temperature until the white smoke disappears. At the same time do blank test and parallel test.
[0027] (4) After the white smoke is exhausted, increase the temperature of the electric furnace to the temperature of the previous constant-weight crucible, and let the crucible with residue continue to have a constant weight on the ...
Embodiment 2
[0035] (1) Dry the quartz sand sample in a 105°C oven to constant weight in advance to remove the influence of moisture.
[0036] (2) Place the platinum crucible on the electric furnace with constant weight. Transfer to a desiccator for later use. Note its weight m1.
[0037] (3) Weigh 1.0000g of the dried quartz sand sample into the platinum crucible that has been treated with constant weight, and record the sample weight m0. Wet the sample with a small amount of water and add 5 drops of concentrated perchloric acid (HClO 4 The content is 60-70%), add 40ml HF (concentrated), and add 2ml 50% volume concentration of HNO 3 Solution to help dissolve. Heat on the electric stove at low temperature until the white smoke disappears. At the same time do blank test and parallel test.
[0038] (4) After the white smoke is exhausted, increase the temperature of the electric furnace to the temperature of the previous constant-weight crucible, and let the crucible with residue continu...
PUM
Login to View More Abstract
Description
Claims
Application Information
Login to View More 